LogTag Recorders USRIC-8 Product User Manual

Usb pdf temperature recorder
Hide thumbs Also See for USRIC-8:

Advertisement

Quick Links

LogTag Recorders Ltd
Find Quality Products Online at:
USRIC-8(M)
USB PDF Temperature Recorder
Product User Guide
Document Release Version: 2
Published 16/08/2016
Copyright © 2004-2016, LogTag
GlobalTestSupply
www.
 
 
 
 
 
 
 
 
®
Recorders
.com
sales@GlobalTestSupply.com

Advertisement

Table of Contents
loading

Summary of Contents for LogTag Recorders USRIC-8

  • Page 1 LogTag Recorders Ltd USRIC-8(M) USB PDF Temperature Recorder           Product User Guide       Document Release Version: 2 Published 16/08/2016 ® Copyright © 2004-2016, LogTag Recorders GlobalTestSupply www. .com Find Quality Products Online at: sales@GlobalTestSupply.com...
  • Page 2: Table Of Contents

    Stefan Lenz features, added alarm configuration section, updated factory profile page GlobalTestSupply ® www. .com Find Quality Products Online at: Page 2 of 15 USRIC-8(M) Product User Guide, Revision 2, copyright © 2004-2016, sales@GlobalTestSupply.com LogTag Recorders . All rights reserved.
  • Page 3: Safety Information

    ... the device is stored and operated according to LogTag Recorders ’ recommendations. Disclaimer The USRIC-8(M) monitors temperature exposure and not the quality of the goods it accompanies. Its purpose is to signal if product quality evaluation/testing is required. Typographical Conventions...
  • Page 4: Introduction

    Buttons button; can be used to start the unit or place an START Depending on the configuration, the USRIC-8(M) may produce all, some or none of /Mark inspection mark in the data listing the files.
  • Page 5: Standard Configuration Options

    Analyzer will scan all USB ports and display the configuration options for connected USRIC-8(M)‘s. Although you can configure many devices at the same time, it is practical to limit the number of devices to about 10, using a powered USB hub. It is not possible to configure different models at the same time.
  • Page 6: Finalising The Configuration

    LogTag Analyzer. A primary upper alarm must be entered before more upper alarms If you configure the USRIC-8(M) to start after a delay period, the can be entered. recorder will not immediately record temperature readings after...
  • Page 7: Marking A Reading With An Inspection Mark

    Manually If you have disabled file generation, the USRIC-8(M)'s green OK You can configure a USRIC-8(M) so it can be stopped with the STOP indicator will blink once every second. button. This feature is useful when you take the recorder out of a shipment and don’t want to falsify the statistics with readings taken...
  • Page 8: Unplugging

    Unplugging You can unplug a USRIC-8(M) at any time; there is no need to stop the device via the shortcut menu in the notification area on the taskbar. If you plug a unit into a USB port during a start delay, the delay period will re-start when the unit is unplugged.
  • Page 9: Light Patterns On Usb Recorders

    2 ALERT for the recorder to stop. seconds The USRIC-8(M) is connected to a USB port and waiting for USB Two quick flashes of the green indicator Ready for USB communication. every second The USRIC-8(M) is generating files. No USB activity will be observed...
  • Page 10: Interpreting The Data

    LogTag_[serial_number]_[trip number]_[file creation date]_file creation time]_[OK or ALM]. USB Paused Readings A gap is shown in the graph where the USRIC-8(M) was plugged into Recorder Information and Configuration a USB port at the time it would otherwise have taken a reading.
  • Page 11: Data Evaluation - Report With Multiple Alarms

    Alarm Status Box Recorder Information and Configuration This shows at a glance if the USRIC-8(M) recorded alarm conditions On recorders with multiple alarms these sections are combined and ✖ during the trip (showing a red...
  • Page 12: Data Evaluation - Data List

    Marked readings In the data list readings are marked after the temperature value..with a + symbol where the USRIC-8(M) has been downloaded with LogTag ® Analyzer.
  • Page 13: Usric-8(M) Factory Presets

    If a default configuration does not suit, customers can compile their own profile by specifying the parameters in the tables below when ordering. ® Please note that minimum order quantities apply for USRIC-8(M) recorders with profiles not stocked by LogTag Recorders .
  • Page 14 Accumulative = temperature readings are above (below) the threshold for the total time defined in the activation delay time, but may not necessarily be sequential. Only on model "M" with multiple alarms. GlobalTestSupply ® www. .com Find Quality Products Online at: Page 14 of 15 USRIC-8(M) Product User Guide, Revision 2, copyright © 2004-2016, sales@GlobalTestSupply.com LogTag Recorders . All rights reserved.
  • Page 15: Technical Specifications

    Technical Specifications Model Numbers Environmental USRIC-8 - Single Trip PDF Temperature Recorder with dual alarms IEC 60529: IP64 with USB cap fitted USRIC-8M - Single Trip PDF Temperature Recorder with 6 alarms Fits into IP67 Protective Enclosure 200-000020 Temperature Sensor Measurement Range Case Material -25°C to +60°C (-13°F to +140°F)

This manual is also suitable for:

Usric-8m

Table of Contents