Certification
6.2 EMC and Environmental Type Tests
6.2

EMC and Environmental Type Tests

The RUGGEDCOM RS401 has passed the following EMC and environmental tests.
IEC 61850-3 EMC Type Tests
IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
IEC 61000-4-5
IEC 61000-4-6
IEC 61000-4-8
IEC 61000-4-29
IEC 61000-4-11
IEC 61000-4-12
38
IEC 61000-6-2
Electromagnetic Compatibility (EMC) – Part 6-2: Generic Standards – Immunity
for Industrial Environments
Test
ESD
Radiated RFI
Burst (Fast
Transient)
Surge
Induced (Con-
ducted) RFI
Magnetic Field
Voltage Dips
and Interrupts
Damped
Oscillatory
Description
Enclosure
Contact
Enclosure Air
Enclosure Ports
Signal Ports
DC Power Ports
AC Power Ports
Earth
Ground Ports
Signal Ports
DC Power Ports
AC Power Ports
Signal Ports
D.C Power Ports
AC Power Ports
Earth
Ground Ports
Enclosure Ports
DC Power Ports
AC Power Ports
Signal Ports
DC Power Ports
AC Power Ports
Test Levels
±8 kV
±15 kV
20 V/m
±4 kV at 2.5 kHz
±4 kV
±4 kV
±4 kV
±4 kV Line-to-Earth,
±2 kV Line-to-Line
±2 kV Line-to-Earth,
±1 kV Line-to-Line
±4 kV Line-to-Earth,
±2 kV Line-to-Line
10 V
10 V
10 V
10 V
40 A/m continuous,
1000 A/m for 1 s
30% for 0.1 s, 100% for 0.05 s
30% for 1 period,
60% for 250 periods
100% for 5 periods,
2
100% for 50 periods
2.5 kV common, 1 kV dif-
ferential mode at 1 MHz
2.5 kV common, 1 kV dif-
ferential mode at 1 MHz
2.5 kV common, 1 kV dif-
ferential mode at 1 MHz
Installation Manual, 01/2020, C79000-G8976-1017-09
Severi-
ty Lev-
els
4
4
 
 
4
4
4
4
3
4
3
3
3
3
 
 
 
 
3
3
3
RUGGEDCOM RS401