Installing the Device
2.6.2 Connecting DC Power
1.
2.
3.
4.
18
Connect the positive wire from the power source to the positive/hot (+/H) termi-
nal on the terminal block.
1
2
3
Positive/Hot (+/H) Terminal
1
Negative/Neutral (-/N) Terminal
2
Surge Ground Terminal
3
Braided Ground Cable
4
Figure 2.10
Terminal Block Wiring
Connect the negative wire from the power source to the negative/neutral (-/N)
on the terminal block.
Using a braided wire or other appropriate grounding wire, connect the surge
ground terminal to the chassis ground connection. The surge ground terminal is
used as the ground conductor for all surge and transient suppression circuitry in-
ternal to the unit.
Connect the ground terminal on the power source to the chassis ground termi-
nal on the device. For more information, refer to
15)".
"Grounding the Device (Page
RUGGEDCOM RS401
Installation Manual, 01/2020, C79000-G8976-1017-09