Siemens SIMATIC NET RUGGEDCOM RS401 Installation Manual page 46

Rugged ethernet switches
Hide thumbs Also See for SIMATIC NET RUGGEDCOM RS401:
Table of Contents

Advertisement

IEC 61000-4-16
IEC 61000-4-17
IEC 60255-5
IEEE 1613 (C37.90.x) EMC Immunity Type Tests
Note
The RUGGEDCOM RS401 meets Class 2 requirements for an all-fiber configuration
and Class 1 requirements for copper ports.
Dielectric Strength
Environmental Type Tests
RUGGEDCOM RS401
Installation Manual, 01/2020, C79000-G8976-1017-09
Test
Mains Frequen-
cy Voltage
Ripple on DC
Power Supply
Dielectric
Strength
H.V. Impulse
Description
ESD
Enclosure Contact
Radiated RFI
Fast Transient
Earth Ground Ports
Oscillatory
Test
IEC 60068-2-1
Cold Temperature
IEC 60068-2-2
IEC 60068-2-30
Humidity (Damp
IEC 60255-21-1
IEC 60255-21-2
6.2 EMC and Environmental Type Tests
Description
Signal Ports
DC Power Ports
DC Power Ports
Signal Ports
DC Power Ports
AC Power Ports
Signal Ports
DC Power Ports
AC Power Ports
Enclosure Air
Enclosure Ports
Signal Ports
DC Power Ports
AC Power Ports
Signal Ports
DC Power Ports
1 kV Common and Differential Mode at 1 MHz
AC Power Ports
1 kV Common and Differential Mode at 1 MHz
Signal Ports
DC Power Ports
AC Power Ports
Description
Dry Heat
Heat, Cyclic)
Vibration
Shock
Test Levels
30 V Continuous, 300 V for 1 s
30 V Continuous, 300 V for 1 s
10%
2 kVac (Fail-Safe Relay Output)
1.5 kVDC
2 kVAC
5 kV (Fail-Safe Relay output)
5 kV
5 kV
Test Levels
±8 kV
±15 kV
35 V/m
±4 kV at 2.5 kHz
±4 kV
±4 kV
±4 kV
2.5 kV Common Mode at 1 MHz
2 kVAC
1.5 kVDC
2 kVAC
Test Levels
Test Ad
-40 °C (-40 °F), 16 Hours
Test Bd
85 °C (185 °F), 16 Hours
Test Db
95% (non-condensing),
55 °C (131 °F), 6 cycles
2 g at 10-150 Hz
30 g at 11 ms
Certification
Severi-
ty Lev-
els
4
4
3
 
 
 
 
 
 
39

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SIMATIC NET RUGGEDCOM RS401 and is the answer not in the manual?

Questions and answers

Table of Contents