Siemens SIMATIC NET SCALANCE XC-200 Operating Instructions Manual

Table of Contents

Advertisement

Quick Links

SIMATIC NET
Industrial Ethernet switches
SCALANCE XC-200
Operating Instructions
04/2018
C79000-G8976-C442-04
___________________
Introduction
___________________
Safety notices
___________________
Description of the device
___________________
Mounting
___________________
Connecting up
Maintenance and
___________________
troubleshooting
___________________
Technical specifications
___________________
Dimension drawings
___________________
Certifications and approvals
1
2
3
4
5
6
7
8
9

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIMATIC NET SCALANCE XC-200

  • Page 1 ___________________ Introduction ___________________ Safety notices ___________________ SIMATIC NET Description of the device ___________________ Mounting Industrial Ethernet switches SCALANCE XC-200 ___________________ Connecting up Maintenance and ___________________ troubleshooting Operating Instructions ___________________ Technical specifications ___________________ Dimension drawings ___________________ Certifications and approvals 04/2018 C79000-G8976-C442-04...
  • Page 2 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Table Of Contents

    Table of contents Introduction ............................. 5 Safety notices ............................11 Recommendations on network security .................. 12 Description of the device ........................17 Product overview ........................17 3.1.1 Accessories ..........................19 3.1.2 Spare parts ..........................21 Device views ........................... 22 3.2.1 Device view of a SCALANCE XC206-2 (ST/BFOC) ...............
  • Page 4 Table of contents Connecting up............................49 Safety when connecting up ....................49 Wiring rules ..........................51 Power supply .......................... 51 Signaling contact ........................53 Serial interface ........................55 Functional ground ........................56 Maintenance and troubleshooting ......................57 Downloading new firmware using TFTP without WBM and CLI ..........57 Restoring the factory settings ....................
  • Page 5: Introduction

    Introduction Purpose of the Operating Instructions These operating instructions support you when installing and connecting up devices of the SCALANCE XC-200 product group. The configuration and the integration of the devices in a network are not described in these operating instructions. Validity of the Operating Instructions These operating instructions apply to the following devices: ●...
  • Page 6 ● On the data medium that ships with some products: – Product CD / product DVD – SIMATIC NET Manual Collection ● On the Internet pages of Siemens Industry Online Support (https://support.industry.siemens.com/cs/ww/en/ps/15247) Documentation on configuration You will find detailed information on configuring the devices in the following configuration manuals: ●...
  • Page 7 ● on the data medium that ships with some products: – Product CD / product DVD – SIMATIC NET Manual Collection ● On the Internet pages of Siemens Industry Online Support (https://support.industry.siemens.com/cs/ww/en/ps/24185/man). Further documentation In the system manuals "Industrial Ethernet / PROFINET Industrial Ethernet" and "Industrial Ethernet / PROFINET passive network components", you will find information on other...
  • Page 8 ● On the Internet under the following address: 50305045 (https://support.industry.siemens.com/cs/ww/en/view/50305045) Catalogs You will find the article numbers for the Siemens products of relevance here in the following catalogs: ● SIMATIC NET Industrial Communication / Industrial Identification, catalog IK PI ● SIMATIC Products for Totally Integrated Automation and Micro Automation, catalog ST 70 ●...
  • Page 9 Siemens’ products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. Use of product versions that are no longer supported, and failure to apply the latest updates may increase customers’...
  • Page 10 Introduction Electrostatic discharge NOTICE Electrostatic sensitive devices (ESD) Electronic modules contain electrostatic sensitive components These components can easily be destroyed if handled incorrectly. Note the following instructions to avoid damage. • Touch electronic modules only when you absolutely need to work on them. •...
  • Page 11: Safety Notices

    Safety notices Read the safety notices Note the following safety notices. These relate to the entire working life of the device. You should also read the safety notices relating to handling in the individual sections, particularly in the sections "Installation" and "Connecting up". CAUTION To prevent injury, read the manual before use.
  • Page 12: Recommendations On Network Security

    ● Evaluate your plant as a whole in terms of security. Use a cell protection concept with suitable products (https://www.industry.siemens.com/topics/global/en/industrial- security/pages/default.aspx). ● When the internal and external network are disconnected, an attacker cannot access internal data from the outside. Therefore operate the device only within a protected network area.
  • Page 13 ● Keep the firmware up to date. Check regularly for security updates for the device. You can find information on this at the Industrial Security (https://www.siemens.com/industrialsecurity) website. ● Inform yourself regularly about security recommendations published by Siemens ProductCERT (https://www.siemens.com/cert/en/cert-security-advisories.htm). ● Only activate protocols that you require to use the device.
  • Page 14 Safety notices 2.1 Recommendations on network security Secure/non-secure protocols and services ● Avoid or disable non-secure protocols and services, for example HTTP, Telnet and TFTP. For historical reasons, these protocols are available, however not intended for secure applications. Use non-secure protocols on the device with caution. ●...
  • Page 15 Safety notices 2.1 Recommendations on network security Interfaces security ● Disable unused interfaces. ● Use IEEE 802.1X for interface authentication. ● Use the function "Locked Ports" to block interfaces for unknown nodes. ● Use the configuration options of the interfaces, e.g. the "Edge Type". ●...
  • Page 16 Safety notices 2.1 Recommendations on network security Protocol Port Port status Factory setting Authentication Encryption TELNET TCP/23 Open Open (when configured) TCP/22 Open Open (when configured) HTTP TCP/80 Open Open (when configured) HTTPS TCP/443 Open Open SNMP UDP/161 Open Open (when configured) (when configured) PROFINET...
  • Page 17: Description Of The Device

    Description of the device Product overview Article numbers For some devices, there are two versions with different article numbers. The two variants differ only in their factory settings. All other properties are identical. Device Description Article number Article number (Ethernet/IP) (PROFINET) SCALANCE XC206-2 (ST/BFOC) 6 x 10/100 Mbps RJ-45 ports, 6GK5 206-2BB00-2AC2...
  • Page 18 Description of the device 3.1 Product overview Factory settings EtherNet/IP variants ● Industrial Ethernet protocol: Ethernet/IP ● Base Bridge mode: 802.1Q VLAN Bridge ● Redundancy mechanism: RSTP ● Trust mode: Trust CoS-DSCP ● IGMP Snooping/IGMP Querier: On ● IPv4 Address Collision Detection: Attempt to defend PROFINET variants ●...
  • Page 19: Accessories

    Description of the device 3.1 Product overview Type designation The type designation of a SCALANCE XC-200 is made up of several parts that have the following meaning: Interfaces of devices with optical connectors: Interface Property Pluggable transceiver port with 100/1000 Mbps Gigabit Enhanced Environment Conditions (coated PCB) Components of the product...
  • Page 20 Description of the device 3.1 Product overview C-PLUG Component Description Article number C-PLUG Configuration plug, exchangeable storage medium 6GK1 900-0AB00 for saving configuration data, 32 MB Configuration plug, exchangeable storage medium 6GK1 900-0AQ00 for saving configuration data, 32 MB, coated (con- formal coating) Configuration plug, exchangeable storage medium 6GK1 900-0AB10...
  • Page 21: Spare Parts

    Description of the device 3.1 Product overview Type Property Article number SFP992-1LH+ 1 x 1000 Mbps LC port optical for glass FO cable 6GK5 992-1AP00-8AA0 (single mode) up to max. 70 km SFP992-1ELH 1 x 1000 Mbps LC port optical for glass FO cable 6GK5 992-1AQ00-8AA0 (single mode) up to max.
  • Page 22: Device Views

    Description of the device 3.2 Device views Device views 3.2.1 Device view of a SCALANCE XC206-2 (ST/BFOC) The following figure shows an overview of the components of the SCALANCE XC206-2 (ST/BFOC). ① ⑦ Electrical ports Power supply ② ⑧ Optical ports Signaling contact ③...
  • Page 23: Device View Of A Scalance Xc206-2 (Sc)

    Description of the device 3.2 Device views 3.2.2 Device view of a SCALANCE XC206-2 (SC) The following figure shows an overview of the components of the SCALANCE XC206-2 (SC). ① ⑦ Electrical ports Power supply ② ⑧ Optical ports Signaling contact ③...
  • Page 24: Device View Of A Scalance Xc206-2Sfp

    Description of the device 3.2 Device views 3.2.3 Device view of a SCALANCE XC206-2SFP The following figure provides an overview of the components of SCALANCE XC206-2SFP and the following devices: ● SCALANCE XC206-2SFP G ● SCALANCE XC206-2SFP EEC ● SCALANCE XC206-2SFP G EEC ①...
  • Page 25: Device View Of A Scalance Xc208

    Description of the device 3.2 Device views 3.2.4 Device view of a SCALANCE XC208 The following figure provides an overview of the components of SCALANCE XC208 and the following devices: ● SCALANCE XC208G ● SCALANCE XC208EEC ● SCALANCE XC208G EEC ①...
  • Page 26: Device View Of A Scalance Xc216

    Description of the device 3.2 Device views 3.2.5 Device view of a SCALANCE XC216 The following figure provides an overview of the components of SCALANCE XC216 and SCALANCE XC216EEC. ① ⑦ Electrical ports Signaling contact ② ⑧ Grounding screw Serial interface ③...
  • Page 27: Device View Of A Scalance Xc224

    Description of the device 3.2 Device views 3.2.6 Device view of a SCALANCE XC224 The following figure shows an overview of the components of the SCALANCE XC224. ① ⑦ Electrical ports Signaling contact ② ⑧ Grounding screw Serial interface ③ ⑨...
  • Page 28: Select / Set Button

    Description of the device 3.3 SELECT / SET button SELECT / SET button Position The "SELECT/SET" button is located on the front of the device. Figure 3-1 Position of the "SELECT/SET" button, for example on the SCALANCE XC-200 with 8 ports Setting the display mode To set the required display mode, press the "SELECT/SET"...
  • Page 29 Description of the device 3.3 SELECT / SET button Requirement ● The device is in operation. ● The function "Reset to Factory Defaults" is enabled for the "SELECT / SET" button. Note Reset despite disabled "SELECT/SET" button If you have disabled the "Restore Factory Defaults" function for the "SELECT/SET" button in the configuration, this does not apply during the startup phase, see section "Restoring the factory settings (Page 58)".
  • Page 30: Led Display

    Description of the device 3.4 LED display To define the fault mask, follow the steps below: 1. Switch to display mode D. Display mode D is active if the "DM1" and "DM2" LEDs are lit green.. If another display mode is active, you will need to press the "SET/SELECT" button repeatedly until the "DM1"...
  • Page 31: Rm" Led

    Description of the device 3.4 LED display 3.4.2 "RM" LED The "RM" LED indicates whether or not the device is a redundancy manager and whether or not the ring is operating free of error. LED color LED status Meaning The device is not a redundancy manager. Green The device is a redundancy manager.
  • Page 32: Leds "Dm1" And "Dm2

    Description of the device 3.4 LED display 3.4.5 LEDs "DM1" and "DM2" The "DM1" and "DM2" LEDs indicate which display mode is set. There are 4 display modes (A, B, C and D). Display mode A is the default mode. Depending on the set display mode, the "L1", "L2"...
  • Page 33: Port Leds

    Description of the device 3.4 LED display Meaning in display mode D In display mode D, the "L1" and "L2" LEDs indicate whether the power supply is monitored. L1/L2 LED L1/L2 connector LED color LED status Power supply is not monitored. If the power supply falls below 9.6 V, the signaling contact does not respond.
  • Page 34: C-Plug

    Description of the device 3.5 C-PLUG If there is a connection problem and the type of transmission is fixed (autonegotiation off), the desired status, in other words the set transmission speed (1000 Mbps, 100 Mbps, 10 Mbps) continues to be displayed. If there is a connection problem and autonegotiation is active, the port LED goes off.
  • Page 35 Description of the device 3.5 C-PLUG A C-PLUG stores the current information about the configuration of a device. Note The device can also be operated without a C-PLUG. How it works Operating mode In terms of the C-PLUG, there are three modes for the device: ●...
  • Page 36: Replacing The C-Plug

    Description of the device 3.5 C-PLUG 3.5.2 Replacing the C-PLUG Position of the C-PLUG NOTICE Do not remove or insert a C-PLUG during operation The C-PLUG may only be removed or inserted when the device is turned off. The C-PLUG slot is on the top of the device housing. Replacing a C-PLUG.
  • Page 37: Near Field Communication

    Description of the device 3.6 Near Field Communication Inserting a C-PLUG 1. Turn off the power to the device. 2. The housing of the C-PLUG has a protruding ridge on the long side (B). The slot has a groove at this position. Insert the C-PLUG correctly oriented into the slot. Near Field Communication Information on Near Field Communication ●...
  • Page 38 Description of the device 3.6 Near Field Communication Reading out information To read out information via the SCALANCE XC-200 using NFC, follow the steps below: 1. Turn on Near Field Communication on the SCALANCE XC-200. As default, the function is deactivated. 2.
  • Page 39: Mounting

    Mounting Safety notices for installation Safety notices When installing the device, keep to the safety notices listed below. WARNING If a device is operated in an ambient temperature of more than 60 °C, the temperature of the device housing may be higher than 70 °C. The device must therefore be installed so that it is only accessible to service personnel or users that are aware of the reason for restricted access and the required safety measures at an ambient temperature higher than 60 °C.
  • Page 40 Mounting 4.1 Safety notices for installation WARNING When used in hazardous environments corresponding to Class I, Division 2 or Class I, Zone 2, the device must be installed in a cabinet or a suitable enclosure. Safety notices for use according to ATEX and IECEx If you use the device under ATEX or IECEx conditions you must also keep to the following safety notices in addition to the general safety notices for protection against explosion: WARNING...
  • Page 41: Types Of Installation

    Mounting 4.2 Types of installation Further notes NOTICE Warming and premature aging of the network component due to direct sunlight Direct sunlight can heat up the device and can lead to premature aging of the network component and its cabling. Provide suitable shade to protect the network component against direct sunlight.
  • Page 42: Mounting On Din Rails

    Mounting 4.3 Mounting on DIN rails Mounting on DIN rails Installation Note Note the position of the securing bar, see also section “Dimension drawings SCALANCE XC- 200 (Page 87)“. When supplied, the securing bar is in the wall mounting position. To change the position of the securing bar, refer to the section “Changing the position of the securing bar (Page 46)“.
  • Page 43: Installation On A Standard S7-300 Rail

    Mounting 4.4 Installation on a standard S7-300 rail 3. Lever the securing bar down using a screwdriver as far as it will go. 4. Pull the device away from the bottom of the DIN rail with the bar pulled. Installation on a standard S7-300 rail Installing on an S7-300 standard rail Note Note the position of the securing bar, see also section “Dimension drawings SCALANCE XC-...
  • Page 44: Installation On A Standard S7-1500 Rail

    Mounting 4.5 Installation on a standard S7-1500 rail Removal To remove the device from a standard rail, follow the steps below: 1. Disconnect all connected cables. 2. If necessary, loosen the knurled screw with your hand or a screwdriver. 3. Lever the securing bar down using a screwdriver as far as it will go. 4.
  • Page 45: Wall Mounting

    Mounting 4.6 Wall mounting 4. When you tighten the knurled screw, you cannot release the securing bar (torque 0.5 Nm). The device is additionally fixed. 5. Connect the electrical connecting cables, refer to the section "Connecting up (Page 49)". Removal To remove the device from a standard rail, follow the steps below: 1.
  • Page 46: Changing The Position Of The Securing Bar

    Mounting 4.7 Changing the position of the securing bar To mount the device on a wall, follow the steps below: 1. Prepare the wall mounting with drilled holes and plugs. For the precise dimensions, refer to the section "Dimension drawings (Page 87)". 2.
  • Page 47: General Notes For Sfp Transceivers

    WARNING Use only approved SFP transceivers If you use SFP transceivers that have not been approved by Siemens AG, there is no guarantee that the device will function according to its specifications. If you use unapproved SFP transceivers, this can lead to the following problems: •...
  • Page 48 Mounting 4.8 General notes for SFP transceivers SCALANCE XC-200 Operating Instructions, 04/2018, C79000-G8976-C442-04...
  • Page 49: Connecting Up

    Connecting up Safety when connecting up Safety notices When connecting up the device, keep to the safety notices listed below. WARNING The equipment is designed for operation with Safety Extra-Low Voltage (SELV) by a Limited Power Source (LPS). This means that only SELV / LPS complying with IEC 60950-1 / EN 60950-1 / VDE 0805-1 must be connected to the power supply terminals, or the power supply unit for the equipment power supply must comply with NEC Class 2, as described by the National Electrical Code (r) (ANSI / NFPA 70).
  • Page 50 Connecting up 5.1 Safety when connecting up Safety notices when using the device according to Hazardous Locations (HazLoc) If you use the device under HazLoc conditions you must also keep to the following safety notices in addition to the general safety notices for protection against explosion: WARNING EXPLOSION HAZARD You may only connect or disconnect cables carrying electricity when the power supply is...
  • Page 51: Wiring Rules

    Connecting up 5.2 Wiring rules Wiring rules When wiring use cables with the following AWG categories or cross sections. Wiring rules for ... Screw/spring-loaded termi- nals connectable cable cross sec- without wire end ferrule 0.25 - 2.5 mm tions for flexible cables ... AWG: 24 - 13 with wire end ferrule with plastic fer- 0.25 - 2.5 mm...
  • Page 52 Connecting up 5.3 Power supply CAUTION Damage to the device due to overvoltage The connector of the external power supply is not protected against strong electromagnetic pulses that can, for example, result from lightning strikes or switching large loads. One of the tests used to attest the immunity of devices of the IE switches SCALANCE XC- 200 to electromagnetic interference was the "surge immunity test"...
  • Page 53: Signaling Contact

    Connecting up 5.4 Signaling contact Position and assignment Figure 5-1 Position of the power supply based, for example on the SCALANCE XC-200 with 8 ports and assignment of the terminal block Contact Assignment 24 VDC Ground Ground 24 VDC Signaling contact Information on the signaling contact ●...
  • Page 54 Connecting up 5.5 Serial interface Position and assignment Figure 5-2 Position of the signaling contact based, for example on the SCALANCE XC-200 with 8 ports and assignment of the terminal block Contact Assignment Fault contact 1 Fault contact 2 Signaling faults ●...
  • Page 55: Serial Interface

    Connecting up 5.5 Serial interface Serial interface Information on the serial interface ● Via the serial interface on the device (RJ-11 jack), you can access the Command Line Interface of the device directly via an RS-232 (115200 8N1) connection without assigning an IP address.
  • Page 56: Functional Ground

    Connecting up 5.6 Functional ground Note Pin assignment of the RJ-11 jack on the device The RJ-11 jack on the device has a pinout to match the RJ-11 plug of the connecting cable. Functional ground EMC disturbances are diverted to ground via the functional ground. This ensures the immunity of the data transmission.
  • Page 57: Maintenance And Troubleshooting

    Maintenance and troubleshooting Downloading new firmware using TFTP without WBM and CLI Firmware The firmware is signed and encrypted. This ensures that only firmware created by Siemens can be downloaded to the device. Procedure with Microsoft Windows Using TFTP, you can supply a device with new firmware even when it cannot be reached using WBM or CLI.
  • Page 58: Restoring The Factory Settings

    Maintenance and troubleshooting 6.2 Restoring the factory settings Restoring the factory settings NOTICE Previous settings If you reset, all the settings you have made will be overwritten by factory defaults. NOTICE Inadvertent reset An inadvertent reset can cause disturbances and failures in the configured network. Restoring the factory settings during the startup phase NOTICE Reset despite disabled "SELECT/SET"...
  • Page 59: Technical Specifications

    Technical specifications Technical specifications SCALANCE XC206-2 (ST/BFOC) The following technical specifications apply to the SCALANCE XC206-2 (ST/BFOC). Technical specifications Attachment to Industrial Ethernet Electrical connectors Quantity Connector RJ-45 jack Properties Half/full duplex, MDI-X pinning Transmission speed 10 / 100 Mbps Optical connectors Quantity Connector...
  • Page 60 Technical specifications 7.1 Technical specifications SCALANCE XC206-2 (ST/BFOC) Technical specifications Fusing 2.5 A / 125 V Signaling contact Quantity Design Terminal block, 2 terminals Permitted voltage range 24 VDC Load capability max. 100 mA Permitted ambient conditions Ambient temperature During operation up to 2000 m -40 °C to +70 °C During storage -40 ℃...
  • Page 61: Technical Specifications Scalance Xc206-2 (Sc)

    Technical specifications 7.2 Technical specifications SCALANCE XC206-2 (SC) Technical specifications SCALANCE XC206-2 (SC) The following technical specifications apply to the SCALANCE XC206-2 (SC). Technical specifications Attachment to Industrial Ethernet Electrical connectors Quantity Connector RJ-45 jack Properties Half/full duplex, MDI-X pinning Transmission speed 10 / 100 Mbps Optical connectors...
  • Page 62 Technical specifications 7.2 Technical specifications SCALANCE XC206-2 (SC) Technical specifications Permitted ambient conditions Ambient temperature During operation up to 2000 m -40 °C to +70 °C During storage -40 ℃ to +85 ℃ During transportation -40 ℃ to +85 ℃ Relative humidity During operation at 25 ℃...
  • Page 63: Technical Specifications Scalance Xc206-2Sfp

    Technical specifications 7.3 Technical specifications SCALANCE XC206-2SFP Technical specifications SCALANCE XC206-2SFP The following technical specifications apply to the SCALANCE XC206-2SFP. Technical specifications Attachment to Industrial Ethernet Electrical connectors Quantity Connector RJ-45 jack Properties Half/full duplex, MDI-X pinning Transmission speed 10 / 100 Mbps Slots for pluggable transceivers Quantity Connector...
  • Page 64 Technical specifications 7.3 Technical specifications SCALANCE XC206-2SFP Technical specifications Degree of protection IP20 Dimensions (W x H x D) 60 x 145 x 125 mm Weight 520 g Installation options Wall mounting • Installation on a DIN rail • Mounting on an S7-300 standard rail •...
  • Page 65: Technical Specifications Of Scalance Xc206-2Sfp G

    Technical specifications 7.4 Technical specifications of SCALANCE XC206-2SFP G Technical specifications of SCALANCE XC206-2SFP G The following technical specifications apply to SCALANCE XC206-2SFP G. Technical specifications Attachment to Industrial Ethernet Electrical connectors Quantity Connector RJ-45 jack Properties Half/full duplex, MDI-X pinning Transmission speed 10 / 100 / 1000 Mbps Slots for pluggable transceivers...
  • Page 66 Technical specifications 7.4 Technical specifications of SCALANCE XC206-2SFP G Technical specifications Degree of protection IP20 Dimensions (W x H x D) 60 x 145 x 125 mm Weight 520 g Installation options Wall mounting • Installation on a DIN rail •...
  • Page 67: Technical Specifications Of Scalance Xc206-2Sfp Eec

    Technical specifications 7.5 Technical specifications of SCALANCE XC206-2SFP EEC Technical specifications of SCALANCE XC206-2SFP EEC The following technical specifications apply to SCALANCE XC206-2SFP EEC. Technical specifications Attachment to Industrial Ethernet Electrical connectors Quantity Connector RJ-45 jack Properties Half/full duplex, MDI-X pinning Transmission speed 10 / 100 Mbps Slots for pluggable transceivers...
  • Page 68 Technical specifications 7.5 Technical specifications of SCALANCE XC206-2SFP EEC Technical specifications Design compact Housing material Basic housing Die cast aluminum, powder coated Front cover Polycarbonate (PC-GF10) Properties Coated printed circuit board (conformal coating) Degree of protection IP20 Dimensions (W x H x D) 60 x 145 x 125 mm Weight 520 g...
  • Page 69: Technical Specifications Of Scalance Xc206-2Sfp G Eec

    Technical specifications 7.6 Technical specifications of SCALANCE XC206-2SFP G EEC Technical specifications of SCALANCE XC206-2SFP G EEC The following technical specifications apply to SCALANCE XC206-2SFP G EEC. Technical specifications Attachment to Industrial Ethernet Electrical connectors Quantity Connector RJ-45 jack Properties Half/full duplex, MDI-X pinning Transmission speed 10 / 100 / 1000 Mbps...
  • Page 70 Technical specifications 7.6 Technical specifications of SCALANCE XC206-2SFP G EEC Technical specifications Design compact Housing material Basic housing Die cast aluminum, powder coated Front cover Polycarbonate (PC-GF10) Properties Coated printed circuit board (conformal coating) Degree of protection IP20 Dimensions (W x H x D) 60 x 145 x 125 mm Weight 520 g...
  • Page 71: Technical Specifications Of The Scalance Xc208

    Technical specifications 7.7 Technical specifications of the SCALANCE XC208 Technical specifications of the SCALANCE XC208 The following technical specifications apply to the SCALANCE XC208. Technical specifications Attachment to Industrial Ethernet Electrical connectors Quantity Connector RJ-45 jack Properties Half/full duplex, MDI-X pinning Transmission speed 10 / 100 Mbps Diagnostics interface...
  • Page 72 Technical specifications 7.7 Technical specifications of the SCALANCE XC208 Technical specifications Installation options Wall mounting • Installation on a DIN rail • Mounting on an S7-300 standard rail • Mounting on an S7-1500 standard rail • Mean time between failure (MTBF) MTBF (EN/IEC 61709;...
  • Page 73: Technical Specifications Of Scalance Xc208G

    Technical specifications 7.8 Technical specifications of SCALANCE XC208G Technical specifications of SCALANCE XC208G The following technical specifications apply to SCALANCE XC208G. Technical specifications Attachment to Industrial Ethernet Electrical connectors Quantity Connector RJ-45 jack Properties Half/full duplex, MDI-X pinning Transmission speed 10 / 100 / 1000 Mbps Diagnostics interface Serial interface...
  • Page 74 Technical specifications 7.8 Technical specifications of SCALANCE XC208G Technical specifications Installation options Wall mounting • Installation on a DIN rail • Mounting on an S7-300 standard rail • Mounting on an S7-1500 standard rail • Mean time between failure (MTBF) MTBF (EN/IEC 61709;...
  • Page 75: Technical Specifications Of Scalance Xc208Eec

    Technical specifications 7.9 Technical specifications of SCALANCE XC208EEC Technical specifications of SCALANCE XC208EEC The following technical specifications apply to SCALANCE XC208EEC. Technical specifications Attachment to Industrial Ethernet Electrical connectors Quantity Connector RJ-45 jack Properties Half/full duplex, MDI-X pinning Transmission speed 10 / 100 Mbps Diagnostics interface Serial interface...
  • Page 76 Technical specifications 7.9 Technical specifications of SCALANCE XC208EEC Technical specifications Installation options Wall mounting • Installation on a DIN rail • Mounting on an S7-300 standard rail • Mounting on an S7-1500 standard rail • Mean time between failure (MTBF) MTBF (EN/IEC 61709;...
  • Page 77: Technical Specifications Of Scalance Xc208G Eec

    Technical specifications 7.10 Technical specifications of SCALANCE XC208G EEC 7.10 Technical specifications of SCALANCE XC208G EEC The following technical specifications apply to SCALANCE XC208G EEC. Technical specifications Attachment to Industrial Ethernet Electrical connectors Quantity Connector RJ-45 jack Properties Half/full duplex, MDI-X pinning Transmission speed 10 / 100 / 1000 Mbps Diagnostics interface...
  • Page 78 Technical specifications 7.10 Technical specifications of SCALANCE XC208G EEC Technical specifications Installation options Wall mounting • Installation on a DIN rail • Mounting on an S7-300 standard rail • Mounting on an S7-1500 standard rail • Mean time between failure (MTBF) MTBF (EN/IEC 61709;...
  • Page 79: Technical Specifications Of The Scalance Xc216

    Technical specifications 7.11 Technical specifications of the SCALANCE XC216 7.11 Technical specifications of the SCALANCE XC216 The following technical specifications apply to the SCALANCE XC216. Technical specifications Attachment to Industrial Ethernet Electrical connectors Quantity Connector RJ-45 jack Properties Half/full duplex, MDI-X pinning Transmission speed 10 / 100 Mbps Diagnostics interface...
  • Page 80 Technical specifications 7.11 Technical specifications of the SCALANCE XC216 Technical specifications Installation options Wall mounting • Installation on a DIN rail • Mounting on an S7-300 standard rail • Mounting on an S7-1500 standard rail • Mean time between failure (MTBF) MTBF (EN/IEC 61709;...
  • Page 81: Technical Specifications Of Scalance Xc216Eec

    Technical specifications 7.12 Technical specifications of SCALANCE XC216EEC 7.12 Technical specifications of SCALANCE XC216EEC The following technical specifications apply to SCALANCE XC216EEC. Technical specifications Attachment to Industrial Ethernet Electrical connectors Quantity Connector RJ-45 jack Properties Half/full duplex, MDI-X pinning Transmission speed 10 / 100 Mbps Diagnostics interface Serial interface...
  • Page 82 Technical specifications 7.12 Technical specifications of SCALANCE XC216EEC Technical specifications Installation options Wall mounting • Installation on a DIN rail • Mounting on an S7-300 standard rail • Mounting on an S7-1500 standard rail • Mean time between failure (MTBF) MTBF (EN/IEC 61709;...
  • Page 83: Technical Specifications Of The Scalance Xc224

    Technical specifications 7.13 Technical specifications of the SCALANCE XC224 7.13 Technical specifications of the SCALANCE XC224 The following technical specifications apply to the SCALANCE XC224. Technical specifications Attachment to Industrial Ethernet Electrical connectors Quantity Connector RJ-45 jack Properties Half/full duplex, MDI-X pinning Transmission speed 10 / 100 Mbps Diagnostics interface...
  • Page 84: Mechanical Stability (In Operation)

    Technical specifications 7.14 Mechanical stability (in operation) Technical specifications Installation options Wall mounting • Installation on a DIN rail • Mounting on an S7-300 standard rail • Mounting on an S7-1500 standard rail • Mean time between failure (MTBF) MTBF (EN/IEC 61709; 40 °C) >...
  • Page 85: Cable Lengths

    Technical specifications 7.16 Cable lengths 7.16 Cable lengths The cable lengths listed below apply to the SCALANCE XC-200. Cable Permitted cable length IE TP torsion cable 0 to 45 m with IE FC Outlet RJ-45 + 10 m TP cord + 10 m TP cord IE TP torsion cable 0 to 55 m...
  • Page 86 Technical specifications 7.17 Switching properties Full wire speed switching 23496 1024 11973 1280 9615 1518 8127 Note The number of SCALANCE XC-200 modules connected in a line influences the entire frame delay. When a frame passes through the IE switch, this is delayed by the store-and-forward function of the SCALANCE XC-200 by 10-130 microseconds (at 100 Mbps).
  • Page 87: Dimension Drawings

    Dimension drawings Dimension drawings SCALANCE XC-200 Note Dimensions are specified in mm. Front view ● SCALANCE XC206-2 (ST/BFOC) ● SCALANCE XC206-2 (SC) ● SCALANCE XC206-2SFP ● SCALANCE XC206-2SFP G ● SCALANCE XC206-2SFP EEC ● SCALANCE XC206-2SFP G EEC ● SCALANCE XC208 ●...
  • Page 88 Dimension drawings 8.1 Dimension drawings SCALANCE XC-200 ① Securing bar in the rail mounting position ② Securing bar in the wall mounting position (as supplied). Figure 8-1 Width and height Front view ● SCALANCE XC216 ● SCALANCE XC216EEC ● SCALANCE XC224 SCALANCE XC-200 Operating Instructions, 04/2018, C79000-G8976-C442-04...
  • Page 89 Dimension drawings 8.1 Dimension drawings SCALANCE XC-200 ① Securing bar in the rail mounting position ② Securing bar in the wall mounting position (as supplied). Figure 8-2 Width and height SCALANCE XC-200 Operating Instructions, 04/2018, C79000-G8976-C442-04...
  • Page 90 Dimension drawings 8.1 Dimension drawings SCALANCE XC-200 Side view of the SCALANCE XC-200 ① Securing bar in the rail mounting position ② Securing bar in the wall mounting position (as supplied). Figure 8-3 Depth SCALANCE XC-200 Operating Instructions, 04/2018, C79000-G8976-C442-04...
  • Page 91 Dimension drawings 8.1 Dimension drawings SCALANCE XC-200 Drilling template for wall mounting Figure 8-4 Drilling template with securing bar in the wall mounting position (as supplied) SCALANCE XC-200 Operating Instructions, 04/2018, C79000-G8976-C442-04...
  • Page 92 Dimension drawings 8.1 Dimension drawings SCALANCE XC-200 SCALANCE XC-200 Operating Instructions, 04/2018, C79000-G8976-C442-04...
  • Page 93: Certifications And Approvals

    You can check which of the following approvals have been granted for your product by the markings on the type plate. Current approvals on the Internet You will find the current approvals for the product on the Internet pages of Siemens Industry Online Support (https://support.industry.siemens.com/cs/ww/en/ps/15273/cert). Notes for the manufacturers of machines The devices are not machines in the sense of the EC Machinery Directive.
  • Page 94 "SIMATIC NET Product Information Use of subassemblies/modules in a Zone 2 Hazardous Area". You will find this document • on the data medium that ships with some devices. • on the Internet pages of Siemens Industry Online Support (https://support.industry.siemens.com/cs/ww/en/view/78381013). Enter the document identification number C234 as the search term. SCALANCE XC-200...
  • Page 95 Area". You will find this document • on the data medium that ships with some devices. • on the Internet pages of Siemens Industry Online Support (https://support.industry.siemens.com/cs/ww/en/view/78381013). Enter the document identification number C234 as the search term. The SIMATIC NET products meet the requirements of the EC directive 94/9/EC "Equipment and Protective Devices for Use in Potentially Explosive Atmospheres”.
  • Page 96 Certifications and approvals IECEx The SIMATIC NET products meet the requirements of explosion protection according to IECEx. IECEx classification: Ex nA IIC T4 Gc DEK 14.0025X The products meet the requirements of the following standards: ● IEC 60079-15 (Explosive atmospheres - Part 15: Equipment protection by type of protection "n") ●...
  • Page 97 Certifications and approvals RoHS The SIMATIC NET products described in these operating instructions meet the requirements of the EC directive 2011/65/EC for the restriction of the use of certain hazardous substances in electrical and electronic equipment: Applied standard: ● EN 50581 The product meets the requirements of the standards: ●...
  • Page 98 Certifications and approvals Approved for use in Cl. 1, Div. 2, GP A, B, C, D T4 Cl. 1, Zone 2, GP IIC T4 Report no. E240480 The product meets the requirements of the AS/NZS 2064 standard (Class A). MSIP 요구사항 - For Korea only A급...
  • Page 99 ● "Industrial Ethernet / PROFINET Industrial Ethernet" System Manual (https://support.industry.siemens.com/cs/ww/en/view/27069465) ● "Industrial Ethernet / PROFINET - Passive Network Components" System Manual (https://support.industry.siemens.com/cs/ww/en/view/84922825) ● "EMC Installation Guidelines" configuration manual (https://support.industry.siemens.com/cs/ww/en/view/60612658)
  • Page 100 Certifications and approvals SCALANCE XC-200 Operating Instructions, 04/2018, C79000-G8976-C442-04...
  • Page 101: Index

    Index Factory settings, 28, 58 Fault mask, 29 Fault/error status, 31 Firmware, 31, 57 Approvals, 93 Article number, 21 Article numbers, 17 Attachment to Industrial Ethernet, 59, 61, 63, 65, 67, 69, 71, 73, 75, 77, 79, 81, Glossary, 8 Grounding, 22, 23, 24, 25, 26, 27, 56 Grounding screw, 22, 23, 24, 25, 26, 27 Button, 57...
  • Page 102 Index Permitted ambient conditions, 21, 60, 62, 63, 65, 67, 69, 71, 73, 75, 77, 79 , 81, 83 PLUG, 34 Pluggable transceiver SFP, 6, 20, 20, 21 Power supply, 19, 22, 23, 24, 25, 26, 27, 52 Reset device, 28, 58, 58 Reset to Factory Defaults, 29, 58 S7-1500, 44 S7-300, 43...

Table of Contents