4. Component Expansion/Function Enhancement
Installing Long Wave SFP+ Modules (16Gbit/s)
IMPORTANT
Make sure to record the connecting port for the disconnected FC cable.
6
Remove the Short wave SFP+ module (16Gbit/s).
(1)
Open the Short wave SFP+ module (16Gbit/s) lever upward.
(2)
Pull the Short wave SFP+ module (16Gbit/s) straight out of the port cage.
IMPORTANT
Make sure to store the removed Short wave SFP+ module (16Gbit/s) with the fixing lever and the
connector cover attached.
7
Install the Long wave SFP+ module (16Gbit/s).
(1)
Remove the connector cover attached to the port of the Long wave SFP+ module (16Gbit/s) and
open the lever.
IMPORTANT
Keep the removed connector cover in a safe place where they will not be lost.
(2)
Check the direction of the Long wave SFP+ module (16Gbit/s) and insert it all the way into the port
gauge.
(3)
Close the Long wave SFP+ module (16Gbit/s) lever downward.
8
Connect the FC cable that is disconnected in
Connect the FC cable connector to the FC port on the Long wave SFP+ module (16Gbit/s).
9
Repeat
Step 5
10
If a wrist strap is used, remove the wrist strap.
SFP+ module
Lever
• When connecting the FC cables, position them so that they will not obstruct
replacement of the power supply unit or controllers by the maintenance
engineer.
through
Step 8
to replace multiple SFP+ modules (16Gbit/s).