Table Of Zones; Interpreting Zone Diagnostics - Directed Electronics 554R Owner's Manual

Combination remote start alarm system
Hide thumbs Also See for 554R:
Table of Contents

Advertisement

table of zones

A zone is represented by the LED flashes used by the system to
identify a particular type of input. Standard input assignments are
listed in the following table.
ZONE
(Number of
DESCRIPTION
LED Flashes)
1
Instant trigger - hood pinswitch
2
Instant trigger - a heavier impact detected by the shock sensor
3
Door switch trigger
4
Instant trigger - for optional sensors
5
Ignition trigger

interpreting zone diagnostics

Warn Away responses are not reported by the arming or
disarming diagnostics. If you receive a Bypass notification when
arming or a Tamper Alert notification when disarming, look at
the LED or transceiver LCD. Active or triggered zones will be
indicated by a pattern of blinks by the LED or the transceiver
icon will indicate the triggered zone.
Example
If Zone 3 was active or triggered, the LED will blink three times
with a two-second pause. Then it will blink three times again,
and repeat until the ignition is turned on and the door icon (9)
will be displayed on the transceiver.