23.7
Adjusting the cup heater
temperature
To modify the cup heater temperature, proceed as
follows:
ENTER
Hold down the ENTER button for at least 5 seconds.
(x 5 secs.)
Scroll the menu until the item is highlighted
01 SERV. BOILER PRESS
02 COFFEE WATER TEMP.
03 GROUPS TEMPERAT.
04 CUP HEATER TEMP.
Enter
Confi rm to access the menu
CUP HEATER

Modify the parameter: increase or decrease
ENTER
Confi rm to exit the menu.
01 SERV. BOILER PRESS
02 COFFEE WATER TEMP.
03 GROUPS TEMPERAT.
04 CUP HEATER TEMP.

To exit the programming menu
X
Cup heater temperature(70 ÷ 114 °C).
i
If a temperature above 114°C is set, the indication
"CUP HEATER ON" appears on the display and the cup
heater's continuous operation is enabled.
i
If setting a temperature below 70°C, the indication
"CUP HEATER--" appears on the display and the cup
heater is disabled.
Technical manual
X °C
23.8
Programming of Energy Saving time
and groups stand-by.
To program the machine (Energy Saving) and groups
(stand-by) start-up and operating times at reduced
temperature, proceed as follows.
Setting the machine START-UP TIME:
ENTER
Hold down the ENTER button for at least 5 seconds.
(x 5 secs.)
Scroll the menu until the item is highlighted
05 ENERGYSAVE TIMING
06 WORKING MODE
07 STBY MODE
08 AUTOSTEAMER MODE
ENTER
Confi rm to access the menu
Machine start-up time
ON TIME
HR:MN
Set the time for the machine to start. To switch from

hours (HR) to minutes (MN) press the () key.
Once the minutes (MN) are set, press the () key to
move to the next display.
Time of the fi rst stand-by period of the delivery groups:
STANDBY 1 TIME
FROM HR:MN
Set the start time for stand-by To switch from hours

(HR) to minutes (MN) press the () key.
Once the minutes (MN) are set, press ().
STANDBY 1 TIME
TO HR:MN
Set the end time for stand-by To switch from hours (HR)

to minutes (MN) press the () key.
Once the minutes (MN) are set, press ().
You can now program the time for the second stand-by
period.