Regeneration Request - Wega Concept Use And Maintenance Manual

Table of Contents

Advertisement

The build-up of lime scale deposits in the hydraulic
!
circuit and boiler inhibits thermal exchange, thus
compromising proper operation of the machine.
Heavy incrustation of the boiler may cause long
machine shutdowns and invalidate the warranty
in any case, because it indicates regeneration has
been neglected.
In order to keep the softener, and hence the machine,
in perfect operating condition, it is necessary to
regenerate it regularly, based on use of the softener and
hardness of the water used. The table below shows the
quantity of softened water based on hardness in various
units of measure:
F°: French degree
D°: German degree = 1.8 °F
mg CaCO
3
For further information on softener installation, start-
up and regeneration, refer to the instruction manual.
Amount of softened water based on hardness
30
40
16,5
22
mg CaCO
30
40
3
8 litres
1000 lt
900 lt
12 litres
1500 lt
1350 lt
16 litres
2100 lt
1800 lt
Technical manual
60
80
33
44
salt
60
80
700 lt
500 lt
1.0 kg
1050 lt
750 lt
1.5 kg
1400 lt
1000 lt
2.0 kg
12.2

Regeneration request

I f t h e f u n c t i o n h a s
been enabled during the
programming, the system
measures the amount of
water used by the machine
and prompts the user for
regeneration (fl ashing of "WATER
SOFTENER REGENERATION")
when the set amount has been
exceeded.
Once the regeneration has been carried out, the
counter must be reset.
Proceed as follows:
Insert the USB drive in the appropriate reader (
) key of the navigator for
hold down the (
5 seconds: display of litres set and amount
of water used;
to reset the counter, hold down the same
key () of the navigator for another 5
seconds;
when fi nished, remove the USB drive.
REGENER. SOFTENER
000025
Counter for the amount of
water used
Wegaconcept
7
7);
001500
Amount of water
set in litres