23.10 Standby Mode - Wega Concept Use And Maintenance Manual

Table of Contents

Advertisement

REDUCED SETPOINT
ENSAV TEMP. XXX.C
Set the temperature of the entire machine in the en-

ergy saving phase
ENTER
Confi rm to exit the menu.
05 ENERGYSAVE TIMING
06 WORKING MODE
07 STBY MODE
08 AUTOSTEAMER MODE

To exit the programming menu
i
To program the single delivery groups stand-by
time and the machine energy saving time, refer to
previous paragraph.
Technical manual

23.10 Standby mode.

This option lets you use the daytime energy savings
mode in two ways:
TIMER Operates according to programmed time
periods (see par. 23.8)
AUTO Self-learning of the machine: during the fi rst
week of operation, the system records all deliveries
provided on each group at each hour. After a week
of operation, the system places the preset groups
in standby, (see previous chapter), referring to the
minimum programmable number of servings/hour
(automatic stand-by threshold).
ENTER
Hold down the ENTER button for at least 5 seconds.
(x 5 secs.)
Scroll the menu until the item is highlighted
05 ENERGYSAVE TIMING
06 WORKING MODE
07 STBY MODE
08 AUTOSTEAMER MODE
ENTER
Confi rm to access the menu
STAND-BY MODE TIME

Modify the TIMER or AUTO operating mode
Based on the selected mode, by pressing the () key,
the proper screen will be displayed:
TIMER
When the group is in stand-by mode (STOP/PROG
LED flashes), if you press the STOP/PROG key for 3
seconds, you can reset the group to its ideal temperature
(this takes about 2 minutes) and dispense doses.
If doses are not dispensed within the programmed
time (see below), the system will go back to stand-by.
To program the time of activation, proceed as
follows: