2.3 I Operation

2.3.1 Switching on the pool circuit
• Check that there are no tools or other foreign objects in the machine.
• Check that the access panel to the technical section is closed properly,
• Set the valves to the following positions: valve
• An incorrect by-pass setting can cause an operating fault on the heat pump.
• Check that the hydraulic connections are tightened correctly and that there are no leaks.
• Check that the appliance is stable.
• Set the water circulation running.
• Close valve
gradually so that the filter pressure is increased by 150 g (0.150 bar).
• Open valves
,
and
condenser and in the filtration circuit). If valves
2.3.2 Switching on the air heating circuit
• Open the filling valve on the hydraulic connection kit; see "1.2.2 Dehumidifier water circuit" to fill the dehumidifier
water circuit at the expansion chamber.
• If there is a risk of frost, add glycol water (maximum 20%).
• Using the pressure gauge valve, check the pressure. It should be between 1 and 1.5 bar.
• Check the air bleed on the automatic bleeds (the bleed plugs must be loose).
• Pay special attention to the dehumidifier heating water circuit during filling. Once the filling and bleed stage is
complete, the circulating pump should display a power rating of 45 W during operation.
fully open; valves
fully, and then half-open valve
and
,
,
and
: pool water inlet valve
: pool by-pass valve
: pool water outlet valve
: pool water inlet adjusting valve (optional)
: pool water outlet adjusting valve (optional)
(to bleed the air that has built up inside the heat pump
are not fitted, open valve
closed.
fully and half-close valve