2.3.3 Switching on the heat pump
• Check that the filtration pump timer is connected correctly; see "1.3.3 Connecting the filtration
pump (heating priority)".
• Connect the power supply to the heat pump. The message
seconds and the ON LED is lit.
• The screen displays
successfully.
• Check the screen that displays:
The heat pump power is switched on
Press and hold the key
The home screen displays:
If the heat pump is in standby, press one of the interface buttons briefly.
The interface language can be changed: English, French or Italian. See § "2.3.4 Set the interface language"
2.3.4 Set the interface language
• From the home screen press and hold
• Select "INSTALLATION MENU" and press
• Select "MISCELLANEOUS" menu and press
• Select the setting "PH09" and press
• Select the language (English, French or Italian) and press
• Press
to exit. Pressing
11
for several seconds and then the RUN LED is lit to confirm that the software has loaded
(3 seconds).
The date and time set (see § "2.3.5 Adjusting the heat pump
timer (RTC)"
Water return temperature dehumidifier heating
Water flow temperature dehumidifier heating
Pool water measured temperature
for 3 seconds,
,
,
,
again takes you back to the main display.
The installer must check the heat pump supply
voltage wiring (see "4.2 I Alarm display").
,