1.4 I Connecting the options

• Any incorrect connection to the terminal can damage the appliance and void its warranty.
• When working on the terminal, there is a risk of electrical return current, injury, damage to
equipment and property and death.
• Use cables with a section of at least 2 x 1 mm².
• Run the cables through cable glands. The cables used for the options and the mains power
supply cable must be kept separate (risk of interference) using a collar inside the appliance
fitted just after the cable glands.
1.4.1 "Remote control" option
• This option duplicates the appliance user interface sot that the appliance can be controlled remotely. To do this, use
the remote control kit available as an accessory.
• For connection, consult the instruction manual supplied with the kit.
1.4.2 Remote "ON/OFF" option
Connecting the remote "ON/OFF" option:
• Any incorrect connection to terminals 6 and 7 can damage the appliance and void its warranty.
• When working on terminals 6 and 7, there is a risk of electrical return current, injury, damage
to equipment and property and death.
• Use cables with a section of at least 2 x 1.5 mm² , type RO2V and a diameter of between 8
and 13 mm.
• Use the cable gland to route the cables in the appliance. The cables used for the options and
the mains power supply cable must be kept separate (risk of interference) using a collar inside
the appliance fitted just after the cable glands.
• This option transfers the "on/off" button function via a switch installed remotely.
• For connection, remove the shunt for terminals 6 and 7 and connect the cable for the switch in its place (potential free
contact, no polarity, 220-240 V ~ 50 Hz).
7
: Heat pump terminal
: Remote "ON/OFF" switch
: Separate connection cable