1.3.2 Connecting the dehumidifier
• Compulsory connection.
• Use cables with a section of at least 2 x 0.75 mm².
• Connect heat pump terminals 8 and 9 to the Zodiac® dehumidifier terminals 3 and 6.
1.3.3 Connecting the filtration pump (heating priority)
• Compulsory connection.
• Use cables with a section of at least 2 x 0.75 mm².
• Connect heat pump terminals 10 and 11 to the filtration timer.
• This function keeps the water temperature constant by checking the water temperature at regular time intervals
(a 15-second cycle every 60 minutes) and also at the end of each air heating cycle via filtration pump control. The
filtration continues to operate if the demand for pool water heating is active.
: Z700 DUO heat pump terminal
: Zodiac® dehumidifier terminal
: filtration timer
: separate connection cable for the "heating priority"
function
: heat pump terminal
: fuse