89
  
 
 
Range of input Operating
voltage (dc)
Max back feed current
Output power factor
Transformer-less, Ungrounded
Synchronization in-rush current
Trip limit and trip time accuracy
Output power temp derate/ max
power ambien
  UL1741 parameters
Three Phase Inverter with Synergy Technology for the 277/480V
SE66.6KUS
SE80KUS
SE100KUS
840-1000
10.4
V>332.4V; 160ms
V< 138.5V; 160ms
304.7V<V<332.4V; 1000ms
138.5V<V<243.8V; 2000ms
F>60.5Hz; 160ms
F<59.3Hz; 160ms
SolarEdge-Three Phase Inverter with Synergy Technology P/N: SExxK-xxxxIxxxx SExxK-xxxxIxxxx
Grid
SE120KUS
0
+/-0.85 to 1
Yes
15.6
120°F/50°C
Three Phase Inverter
with Synergy
 
Technology for the
120/208VGrid
SE43.2KUS
SE50KUS
Unit
370-600
Vdc
Adc
 
 
7.2
Adc
V>144.0V; 160ms
V< 60.0V; 160ms
132.0V<V<144.0V;
1000ms
Vdc
60.0V<V<105.6V;
2000ms
F>60.5Hz; 160ms
F<59.3Hz; 160ms
 

Advertisement