SolarEdge SEK-I Series Installation Manual page 68

Three phase inverter
Table of Contents

Advertisement

and color-coding.
Wire Color
RJ45 Pin #
T568B
1
White/Orange
2
Orange
3
White/Green
4
Blue
5
White/Blue
6
Green
7
White/Brown
8
Brown
Use a non-crimped cable to connect via the gland to the RJ45 port on the inverter's
communication board or, if using a spool of cable, connect as follows:
Insert the cable through the gland.
Remove the cable's external insulation using a crimping tool or cable cutter and
expose eight wires.
Insert the eight wires into an RJ45 connector, as shown in Figure 32 .
Use a crimping tool to crimp the connector.
Connect the Ethernet connector to the RJ45 port on the communication board
as shown in Figure 31 .
For the switch/router side, use a pre-crimped cable or use a crimper to prepare an
RJ45 communication connector.
Connect the cable RJ45 connector to the RJ45 port of the Ethernet router or switch.
You can connect more than one inverter to the same switch/router or to different
switches/routers, as needed. Each inverter sends its monitored data independently
to the SolarEdge Monitoring platform.
(1) The connection does not support RX/TX polarity change. Supporting crossover Ethernet cables depends
on the switch capabilities.
Three Phase Inverter with Synergy Technology P/N: SExxK-xxxxIxxxx SExxK-xxxxIxxxx
Chapter 6: Setting Up Communication with the Monitoring Platform
(1)
T568A
White/Green
Green
White/Orange
Blue
White/Blue
Orange
White/Brown
Brown
Figure 32: Ethernet connector - pin layout
10Base-T Signal
100Base-TX Signal
Transmit+
Transmit-
Receive+
Reserved
Reserved
Received-
Reserved
Reserved