Connector Wiring

Power supply wiring

N
This product is intended to be supplied by a UL Listed
Wire the supplied male power connector (plug) as in figure 5.
Figure 5 — Power connector wiring
C
The length of the exposed (stripped) copper wires is
N
To verify the polarity before connection, plug in the power
supply with no load and check the output with a voltmeter.
W
As an alternative, an Extron PS 124 Universal 12 VDC Power
Supply (part #60-1022-01) can power multiple MTPs or other
Extron 12 VDC devices using only one AC power connector.
Insert the wired plug into the power connector on the rear panel.
Do not power on the device at this time.
power supply with output rated at 12 VDC, 1 A.
Power supply voltage polarity is critical. Incorrect
voltage polarity can damage the power supply and the
product. Identify the power cord negative lead by the
ridges on the side of the cord.
important. The ideal length is 3/16" (5 mm). Longer
bare wires can short together. Shorter wires are not as
secure in the captive screw connectors and could be pulled
out.
Do not tin the stripped power supply leads before
installing the captive screw connector. Tinned wires are
not as secure in the captive screw connectors and could be
pulled out.
The two power cord wires must be kept separate while
the power supply is plugged in. Remove power before
wiring.
MTP 1500RL 15HD RS Series • Installation