Should a setting different to the factory one be requested, carry out the following operations:
1) Turn the arrow of the rotary switch to the desired position with the board not powered.
2) When the board is powered, the percentage corresponding to the selected position will automatically be set.
If the maximum current/load is too low compared to the real operating requirements, may intervene protections against
high absorption of the actuator in closing and opening the retractable, with flashing 1 and 7 errors.
NOTIFICATION SIGNS
Legend of error notifications concerning the RTC R1 board (see the board on page 29)
LED POWER (green)
LED STATUS
DESCRIPTION
Board not powered
OFF
Powered board but disabled control
SLOW FLASHING
Powered board and actuator's manual movement mode on
FAST FLASHING
ON WITH SHORT
Powered board but disabled control and active link with the CAN control station
SWITCHING OFF
Powered board and enabled control (TCD or CAN station).
ON
LED LA STATUS (bi-colour)
LED COLOUR
LED STATUS
-
OFF
RED
ON
GREEN
ON
ORANGE
ON
ORANGE
FLASHING
RETRACTABLE THRUSTER BTR185 - IT GB - REV004B
USAGE / NOTIFICATION SIGNS
DESCRIPTION
With powered board, actuator's manual movement mode on and limit switch
anomaly present
Retractable thruster closed (LSC limit switch enabled)
Retractable thruster open (LSO limit switch enabled)
Retractable thruster neither open nor closed (LSC and LSO limit switches disabled)
Retractable thruster neither open nor closed (LSC and LSO limit switches disa-
bled) and linear actuator moving.