OPERATING / USAGE
GB
OPTION SELECTION DIP-SWITCH
SWITCH
FUNCTION
1
Reserved (always keep off)
Informs the CAN control station that the thruster is in the bow (OFF)
2
Informs the CAN control station that the thruster is in the stern (ON)
3
Reserved (always keep off)
4
Reserved (always keep off)
1 = OFF , 2 = OFF , 3 = OFF , 4 = OFF
FACTORY SETTING:
ACTUATOR CURRENT ROTARY SWITCH
The ten selectable steps (from 0 to 9) allow you to set a percentage (see table) regarding the maximum current/load al-
lowed for the actuator in use.
ROTARY SWITCH
POSITION
0
1
2
3
4
5
6
7
8
9
FACTORY SETTING: position
30
MAXIMUM CURRENT/LOAD %
28%
36%
44%
52%
60%
68%
76%
84%
92%
100%
= 5
DESCRIZIONE
ON
1
2 3 4
ON
1
2
3 4
ON
1
2
3 4
ON
1 2
3
ON
1 2 3
RETRACTABLE THRUSTER BTR185 - IT GB - REV004B
4
4