Download Print this page

Quick BTR1806512 User Manual page 26

Retractable thruster
Hide thumbs Also See for BTR1806512:

Advertisement

Available languages

Available languages

INSTALLATION
GB
WARNING: pay particular attention to avoid interferences between the lid and the hull opening. Too precise con-
tacts will cause damages to the entire moving system.
3) Fix the actuator on the lever again, by inserting the lock pin.
Once the system has been mechanically verifi ed, proceed to adjust the limit switch.
PROCEDURE FOR THE ADJUSTMENT OF THE CLOSING LIMIT SWITCH OF BTR PROPELLER.
WARNING: the following procedure must be carried out by qualified personnel.
WARNING: presence of moving mechanical parts. Pay extreme attention when operating on the BTR propeller if
connected to power.
4) Ensure that all electrical connections have been properly carried
out.
5) Remove the cover from the card box.
Limit switch adjustments must be made in "manual mode".
6) Holding down both buttons on the board(fig. 8 / part. A), connect
power to the RTC R1 electronic control board until the (green)
POWER LED begins flashing rapidly (fig. 8 / part. B).
Then release both buttons.
7) Push the "DOWN" button to open the thruster, as long as the LA
STATUS LED will become green.
8) Push the "UP" button to close the thruster until the ERROR LED
(Red) flashes.
26
FIG. 8
UP
DWN
A
B
C
D
RETRACTABLE THRUSTER BTR185 - IT GB - REV004B
POWER
LA STATUS
ERROR

Advertisement

loading

This manual is also suitable for:

Btr1806524Btr1808512Btr1808524Btr1810512Btr1810524