Inspections Following A First-Time Installation - Pilz PSEN op4F-A Series Operating Manual

Safety light curtain
Table of Contents

Advertisement

OPERATING MANUAL
The table below states the operating ranges based on the number of mirrors used.
Number
of mirrors
1
2
3
• Never use more than three mirrors per device.
• Any dust or dirt on the mirror's reflective surface will drastically reduce the operating range.
2.2.5

Inspections following a first-time installation

Listed below are the control measures that must be taken following a first-time installation,
prior to starting the machine. Tests must be carried out by qualified personnel or directly by
the person in charge of machinery safety / under his or her supervision.
1003067-EN-04
Operating range
(14 mm)
5.1 m
4.3 m
3.7 m
Fig. 16 – Path of test object
Operating range
(30 mm)
16.5 m
13.7 m
11.6 m
PSEN op4F/H-A series
21