Pilz PNOZ mc8p Operating Manual

Pilz PNOZ mc8p Operating Manual

Configurable safety systems pnozmulti
Hide thumbs Also See for PNOZ mc8p:

Advertisement

PNOZ mc8p
Configurable safety systems PNOZmulti
}
Operating Manual-21254-EN-07

Advertisement

Table of Contents
loading

Summary of Contents for Pilz PNOZ mc8p

  • Page 1 PNOZ mc8p Configurable safety systems PNOZmulti Operating Manual-21254-EN-07...
  • Page 2 Preface This document is a translation of the original document. All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies may be made for internal purposes. Suggestions and comments for improving this documentation will be gratefully received.
  • Page 3: Table Of Contents

    General wiring guidelines Connecting the supply voltage Interface assignment Download modified project to the PNOZmulti system Set IP address Connection example Section 7 Operation Messages Section 8 Technical Details Section 9 Order reference Product Accessories Operating Manual PNOZ mc8p 21254-EN-07...
  • Page 4: Operating Manual Pnoz Mc8P

    Introduction Introduction Validity of documentation This documentation is valid for the product PNOZ mc8p. It is valid until new documentation is published. This operating manual explains the function and operation, describes the installation and provides guidelines on how to connect the product.
  • Page 5 Introduction INFORMATION This gives advice on applications and provides information on special fea- tures. Operating Manual PNOZ mc8p 21254-EN-07...
  • Page 6: Overview Scope

    24 - 127 are used they have different properties (see document entitled "Communication Interfaces"). Max. 1 PNOZ mc8p can be connected to the base unit For details of the PNOZmulti base units that can be connected, please refer to the doc- ument "PNOZmulti System Expansion".
  • Page 7: Front View

    Overview Front view Legend EtherNet/IP, Modbus TCP interface IP address: for setting the IP address LEDs: ACT, LINK, STAT, NET EtherNet/IP is registered trademark and patented technology, licensed by ODVA. Operating Manual PNOZ mc8p 21254-EN-07...
  • Page 8: Safety

    Modbus TCP conform to IEEE 802.3. The central controller (scanner) reads input information from the slaves and writes output information to the slaves as part of each cycle. As well as the cyclical transfer of usable data, the expansion module PNOZ mc8p can also be used for diagnostic and commissioning functions.
  • Page 9: Safety Regulations

    Do not open the housing or make any unauthorised modifications. Please make sure you shut down the supply voltage when performing maintenance work (e.g. exchanging contactors). Operating Manual PNOZ mc8p 21254-EN-07...
  • Page 10: Function Description

    TCP are selected and configured in the PNOZmulti Configurator. The base unit and the fieldbus module PNOZ mc8p are connected via a jumper. The fieldbus module is also sup- plied with voltage via this jumper. After the supply voltage is switched on or the control sys- tem PNOZmulti is reset, the fieldbus module PNOZ mc8p is configured and started auto- matically.
  • Page 11: Input And Output Data

    Detailed information on data exchange is available in the document "Communication Inter- faces", under "Fieldbus modules". The number of virtual inputs and outputs can be extended to 128 (see document "Commu- nication Interfaces", under "Fieldbus modules"). Operating Manual PNOZ mc8p 21254-EN-07...
  • Page 12: Block Diagram

    Function description Block diagram Operating Manual PNOZ mc8p 21254-EN-07...
  • Page 13: Installation

    Damage due to electrostatic discharge! Electrostatic discharge can damage components. Ensure against discharge before touching the product, e.g. by touching an earthed, conductive sur- face or by wearing an earthed armband. Dimensions in mm 22,5 94 (3.70") (0.88") Operating Manual PNOZ mc8p 21254-EN-07...
  • Page 14: Connecting The Base Unit And Expansion Modules

    Installation Connecting the base unit and expansion modules You can install a maximum of 1 PNOZ mc8p to the left of the base unit. Connect the base unit and the expansion module as described in the operating instructions for the base units.
  • Page 15: Commissioning

    When installing, you must refer to the guidelines of the EtherNet/IP, Modbus TCPUser Group. Connecting the supply voltage Connect the supply voltage to the base unit: Terminal 24 V and A1 (+): + 24 VDC Terminal 0 V and A2 (-): 0 V Operating Manual PNOZ mc8p 21254-EN-07...
  • Page 16: Interface Assignment

    Set IP address The IP address of the fieldbus module PNOZ mc8p is set using the DIP switch on the front. The first three bytes of the IP address are: 192.168.0. Subnet mask: 255.255.255.0.
  • Page 17 (LSB) IP address: 192.168.0.20 Change IP settings Once the IP addresses of the computer and PNOZ mc8p have been configured, you can change the IP settings of the PNOZ mc8p. Connect the PNOZ mc8p to the computer. Call up the following html page: http://192.168.0.20/config.htm Configure the settings for the PNOZ mc8p.
  • Page 18: Connection Example

    Commissioning Connection example Ethernet-Subscriber Ethernet-Subscriber Operating Manual PNOZ mc8p 21254-EN-07...
  • Page 19: Operation

    The LEDs “POWER”, “DIAG”, “FAULT”, “IFAULT” and “OFAULT” will light up on the base unit. The fieldbus module PNOZ mc8p is configured and started automatically. The LEDs "MS", "NS", "L/A1" and "L/A2" indicate the status of the PNOZ mc8p on the EtherNet/IP, Modbus TCP. Messages...
  • Page 20: Technical Details

    93 % r. h. at 40 °C Humidity Condensation during operation Not permitted Short-term EN 61131-2 EN 61131-2 Vibration In accordance with the standard EN 60068-2-6 EN 60068-2-6 Frequency 5,0 - 500,0 Hz 5,0 - 500,0 Hz Acceleration Operating Manual PNOZ mc8p 21254-EN-07...
  • Page 21 ABS UL 94 V0 Dimensions 94,0 mm 94,0 mm Height Width 22,5 mm 22,5 mm Depth 114,0 mm 114,0 mm Weight 137 g 140 g Where standards are undated, the 2009-10 latest editions shall apply. Operating Manual PNOZ mc8p 21254-EN-07...
  • Page 22: Order Reference

    Order reference Order reference Product Product type Features Order No. PNOZ mc8p Fieldbus module, Ethernet/IP, Modbus TCP 773 730 PNOZ mc8p coated ver- Fieldbus module, Ethernet/IP, Modbus TCP 773 734 sion Accessories Jumper Product type Features Order No. KOP-XE Jumper...
  • Page 23 Back cover Support Technical support is available from Pilz round the clock. Americas Australia Scandinavia Brazil +61 3 95600621 +45 74436332 +55 11 97569-2804 Spain Canada Europe +34 938497433 +1 888-315-PILZ (315-7459) Austria Switzerland +41 62 88979-30 Mexico +43 1 7986263-0...

Table of Contents