Pilz PSEN op4F-A Series Operating Manual page 47

Safety light curtain
Table of Contents

Advertisement

OPERATING MANUAL
PSEN op4F/H-A series
Fig. 42 – T muting timings
The sensors labelled A1/A2 are connected to the muting input (MUTING1) and the sensors
labelled B1/B2 are connected to the MUTING2 input. Sensors ending in "1" are on the same
side of the light curtain and therefore on the opposite side to the sensors ending in "2".
"D" stands for the distance at which the sensors A1/A2 or B1/B2 must be installed and
depends on the package length (L):
D < L
"d1" stands for the maximum distance required between the muting sensors and depends on
the package speed (V):
d1
[cm] = V [m/s] * T12 [s] * 100,
max
"d2" stands for the maximum distance required to accept a muting request and depends on
the package speed (V):
d2
[cm] = V [m/s] * T12 [s] * 100,
max
"T12" stands for the activation delay between MUTING1 and MUTING2, which the operator
can select via ACM.
Fig. 43 – T-Muting connection
1003067-EN-04
47

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents