Pilz PSEN op4F-A Series Operating Manual page 42

Safety light curtain
Table of Contents

Advertisement

OPERATING MANUAL
PNP configuration
The EDM status is not equivalent to that of the OSSD: the timing diagram illustrates the
relationship between cause (OSSD) and effect (EDM), with the maximum permitted delay.
Tc ≥ 350 ms (time between the OSSD transition from OFF-ON and the EDM test)
To ≥ 100 ms (time between the OSSD transition from OFF-ON and the EDM test)
(two different times for the mechanical, positive-guided contact)
EDM disabled:
If EDM is disabled, the EDM input may not be connected.
PNP configuration
42
Fig. 37 – EDM timings
Fig. 38 – EDM connections
PSEN op4F/H-A series
NPN configuration
NPN configuration
1003067-EN-04