Override Timeout - Pilz PSEN op4F-A Series Operating Manual

Safety light curtain
Table of Contents

Advertisement

OPERATING MANUAL
Level
Edge
7.8.2

Override timeout

BCM mode
The timeout of the override status is 120 seconds in both operating modes. If the override
conditions remain active and both contacts remain closed for more than 120 seconds (this
condition only applies when the mode is activated by level), the override will go low after a
maximum of 120 seconds.
ACM mode
The override timeout represents the maximum duration of the override. This time can be set,
from a minimum of one minute to a maximum of 256 minutes.
Once the timeout has elapsed the override ends, even if the conditions that led to the
activation are still present and the override inputs are active.
OVERRIDE STATE: This is an output signal which provides the user with information as to
whether the override inputs are active and the override conditions are present.
1003067-EN-04
BCM configuration: Override mode
LED 8 ON green
LED 8 OFF
ACM configuration: Override mode
Fig. 52 – Override timeout timings
PSEN op4F/H-A series
LEVEL