Minimum Safety Distance - Pilz PSEN op4F-A Series Operating Manual

Safety light curtain
Table of Contents

Advertisement

OPERATING MANUAL
1.2.3

Minimum safety distance

The protective device must be positioned at a specific safety distance (Fig. 3), which
guarantees that the operator cannot reach the danger zone until the hazardous machine
movement has come to a standstill by triggering the light curtain.
In accordance with the standard ISO 13855, this distance depends on 4 factors:
Response time of the light curtain (the time that elapses between the beams being
effectively interrupted and the OSSD contacts opening).
Machine's stopping performance (time that elapses between the light curtain contacts
opening and the hazardous machine movement effectively stopping).
Light curtain's resolution
Approach speed of the object to be detected.
≥ 900 mm at a resolution > 40 mm
H1 =
≤ 300 mm at a resolution > 40 mm
H2 =
S
=
Minimum safety distance in mm
1003067-EN-04
PSEN op4F-A-14-105/1
PSEN op4H-A-30-105/1
PSEN op4F-A-14-120/1
PSEN op4H-A-30-120/1
PSEN op4F-A-14-135/1
PSEN op4H-A-30-135/1
PSEN op4F-A-14-150/1
PSEN op4H-A-30-150/1
PSEN op4F-A-14-165/1
PSEN op4H-A-30-165/1
PSEN op4F-A-14-180/1
PSEN op4H-A-30-180/1
Fig. 3 – Safety distance (vertical)
PSEN op4F/H-A series
1050
1200
1350
1500
1650
1800
9

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents