Reset To Factory Configuration - Pilz PSEN op4F-A Series Operating Manual

Safety light curtain
Table of Contents

Advertisement

OPERATING MANUAL
Identification of light curtain
Serial no.
Firmware version
Configuration ID (check sum of configuration parameters)
Position of light curtain in a cascading
Model name and characteristic data of the light curtain (resolution)
Current protected field configuration (muting or blanking)
Configuration parameters for blanking/muting

6.1 Reset to factory configuration

The user has the option to re-establish the light curtain's factory configuration by operating
the pushbuttons as described below:
1. Press the CONFIRM button and keep it held down for at least 9 s (but not more than
30 s, so that the light curtain is not blocked)
2. The LEDs flash briefly, indicating that the light curtain has been reset to the factory
configuration
3. After the reset has occurred, the light curtain resumes its normal operation with the
factory configuration.
NOTE: Restoring the factory settings will delete the BCM and the ACM
configuration.