Function List - Pilz PSEN op4F-A Series Operating Manual

Safety light curtain
Table of Contents

Advertisement

OPERATING MANUAL

6.2 Function list

PSEN op4F/H-A has two main operating modes: blanking and muting. The settings of the
functions at the receiver associated with LEDs 5 to 8 will change, depending on whether
blanking or muting is selected.
NOTE: The table highlights the default configuration in bold.
Legend for LED display in RX/TX function list
LED off, LED is not relevant for the information in the "Function" column
LED off, LED is relevant for the information in the "Function" column
LED yellow, value in the "Setting" column is valid for the information in the
"Function" column
LED red, value in the "Setting" column is valid for the information in the "Function"
column
LED green, value in the "Setting" column is valid for the information in the
"Function" column
Function
Coding
Selection
of
muting/blanking
EDM
Restart mode
Muting direction
Muting timeout
Activation
of
override
36
List of RX functions in muting mode
(LED 3 lights up yellow)
LED
Setting
No.
2
Code 1
Code 2
No code
3
Muting
Blanking
4
Activated
Deactivated
5
Auto
Manual
6
T (bidirectional)
L (one-directional)
7
10 min
Infinite
8
Level
Edge
PSEN op4F/H-A series
LED status
LEVEL
1003067-EN-04

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents