Probe Mounting; Installation Depth Sliding Fitting - E+E Elektronik EE360 Operation Manual

Moisture in oil transmitter
Hide thumbs Also See for EE360:
Table of Contents

Advertisement

Model
EE360
Model
EE360
3.3

Probe mounting

The probe shall be mounted horizontally or vertically pointing downwards.
For accurate measurement it is of paramount importance to avoid T gradients along the probe. In case
of large T difference between the front and the back of the probe, it is highly recommended to insert the
probe completely into the process. Should this not be possible, place a thermal isolation layer on the
part of the probe outside the process (on the cable side).
General safety instructions for installation
The installation, commissioning and operation of the EE360 may be performed by qualified staff only.
Special attention shall be paid to the correct installation of the probe into the process. In case of inap-
propriate installation there is the risk for the probe to be suddenly expulsed due to the pressure in the
process.
Bending over the sensing probe should be avoided under any circumstances!
Make sure that the surface of the probe is not damaged during installation. A damaged probe surface
may lead to damaged seals and consequently to leakage and pressure loss.
T working range probe:
3.3.1

Installation depth sliding fitting

minimum installation depth
23
(1")
maximum installation depth
64 mm
for 100 mm
(2.5")
164 mm
for 200 mm
(6.5")
364 mm
for 400 mm
(6.5")
1) Refer to ordering guide
Fig. 15
Max. and min. installation detph
Operating instructions for EE360 Moisture in Oil Transmitter
Type
Out 1
Out 2
Type
Modbus RTU
-40...+180 °C
cable:
-40...+150
cable oil resistance:
-40...+80 °C
electronics:
-40...+60 °C
-20...+50 °C
probe /
(3.94")
probe
(7.87")
probe
(15.75")
Outputs
Ratings
0-1V
0-5V
0-10V
0-20mA
4-20mA
(SELV Limited Energy source)
0-1V
0-5V
0-10V
0-20mA
4-20mA
(SELV Limited Energy source)
Ratings
0-5V
(SELV Limited Energy source)
(-40...176 °F)
(-40...302 °F)
(-40...176 °F)
(-40...140 °F)
(with display)
(-4...122 °F)
Terminals
Out 1 (4) –
GND (3)
Out 2 (5) –
GND (3)
Terminals
RS485 A (=D+) (7) –
RS485 B (=D-) (8) –
GND RS485 (6)
19