Product Description; Installation; Installation Of The Housing; Installation Of The Probe - E+E Elektronik EE36 Series Manual

Transmitter for moisture content in oil
Table of Contents

Advertisement

code "cable length"
32
code "probe length"
(1.3")
23
(1")
minimum installation depth
90
resp. 190
(3.5")
(7.5")
maximum installation depth
2.

PRODUCT DESCRIPTION

E+E Transmitter Series EE36 are specially designed for the measurement of
water content in oil.
The measured and the calculated values are available on two free scaleable
and configurable analogue outputs. In addition, an optional relay output can
be used for alarms and process control.
The modular housing enables a user-friendly operation and a quick
replacement of the sensor unit for service purposes.
The construction of the transmitter makes field and local loop calibration an easy task.
3.

INSTALLATION

3.1
The necessary dimensions for the mounting holes can be
found in the drawings below.
metal housing:
polycarbonate housing:
3.2

Installation of the probe

Select a location with environmental conditions that permit an
optimal measurement of the process. The measuring medium
(e.g.: oil) shall be as clean as possible i.e. without contamination.

3.2.1 General safety instructions for installation

Because the sensing probe can be exposed to very high
pressures in the measurement environment, there is the risk of
sudden, unintentional expulsion of the probe during or after
improper installation. Therefore, special precautions should be
taken when working on the sensing probe or in its vicinity.
Bending over the sensing probe should be avoided under
any circumstances!
During the installation of the sensor probe, make sure that
the surface of the sensing probe is not damaged! Damaging
the probe could lead to damaged seals (consequence:
leakage and pressure loss) and to problems during removal
(jamming).
5

Installation of the housing

Hardware

Advertisement

Table of Contents
loading

Table of Contents