Anti -Rotation
Screw
P/N 0001374
¼"-28 Hex Nut
P/N 0001689
Yoke / Arm
Connector
Head
Assembly
FIGURE 17: Installation of Light Head to Arm
Installation and repair of this equipment should be performed by qualified persons
only. Nuvo, Inc. does not warranty any damage occurring as a result of improper
installation.
Make sure the light head is installed to the correct arm when assembling multiple
lights or combination models. Mounting the incorrect light head to the arm can cause
improper arm support, inefficient bulb performance, and /or bulb failure.
• Remove the two screws from the switch assembly cover and pull downward exposing the
switch and the wire connector. See figure 17.
• Insert the wire set from the yoke / arm connector through the hole in the arm/wire junction.
Note: The VistOR PR Light is shown.
5368 KUHL ROAD ● ERIE, PENNSYLVANIA 16510 ● PHONE 814-899-4220 ● FAX 814-899-1410

Installation of Light Head to Arm

9
¼"-28 x 1
/
"
16
Hex Bolt
P/N 0001298
A member of the Medical Illumination International Group
Section 3
Cover
P/N 1002043
Arm
Assembly
Switch Assembly
Cover
Flat Head Screws (2)
P/N 0001320