Activation of DEAD-MAN opening (command always pressed). Releasing the OPEN
command will stop operation
When this function is activated, the OPEN command during opening will stop movement.
06
no
05
If parameter
is
06
Y
If parameter
is
When this function is activated, the OPEN command during opening reverses movement.
06
05
If parameters
and
07
When this function is activated, the OPEN command during pause stops operation.
07
If parameters
and
When this function is activated, the OPEN command during pause causes closing.
08
07
If parameters
and
09
When this function is activated, the OPEN command during closing stops operation,
otherwise it reverses movement.
10
Activation of DEAD-MAN closing (command always pressed). Releasing the CLOSE
command will stop operation
1 1
When this function is activated, the CLOSE command has priority over OPEN, otherwise
OPEN has priority over CLOSE.
12
When this function is activated, the CLOSE command commands closing when released.
As long as CLOSE is activated, the unit stays in closing pre-flashing.
When this function is activated, the CLOSE command during opening stops operation,
13
otherwise the CLOSE command commands reverse immediately or when opening is com-
pleted (see also parameter
When this function is activated, and if parameter
14
commands immediate closing at the end of the opening cycle (stores CLOSE). If parameters
13
14
no
and
are
CLOSE commands immediate closing.
When this function is activated, with the system blocked by a STOP, a next OPEN
15
moves in the opposite direction. If parameter
16
When this function is activated, during closing, the CLOSING SAFETIES stop and allow
motion to resume when they are disengaged, otherwise they immediately reverse opening.
When this function is activated, the CLOSING SAFETIES command closing when they are
17
disengaged (see also parameter
18
When this function is activated, and if parameter
opening cycle to end before executing the closing command provided by the
CLOSING SAFETIES.
19
When this function is activated, during closing, LOOP2 stops and allows motion to resume
when it is disengaged, otherwise it immediately reverses opening.
When this function is activated, LOOP2 commands closing when it is disengaged (see also
20
21
parameter
).
2 1
When this function is activated, and if parameter
cycle to end before executing the closing command provided by LOOP2.
22
When this function is activated: in case of a blackout, once electrical power has been
restored, if an OPEN command is not active the automated system recloses immediately.
LOOP 1 commands opening and, once completed, it closes if disengaged (useful in case
23
of vehicle backing-up with consecutive loops). If disabled, when LOOP 1 is disengaged, it
does not close.
24
When this function is activated, an open or close command is only carried out after
the safeties have been disengaged.
A.D.M.A.P. function
25
When this function is activated, the result is operation of safeties compliant with French
regulations.
the system is ready for opening.
the system is ready for closing.
06
no
are
OPEN will have no effect during opening.
08
no
are
OPEN resets the pause time
08
no
are
OPEN resets the pause time.
14
)
15
no
is
18
).
21
13
no
is
, the CLOSE command
it always closes.
17
Y
is
, the unit will wait for the
Y
is
, the unit will wait for the opening
15
Y
no
= active
= disabled
Y
no
= when opening it stops
= disabled
Y
no
= when opening it reverses
= disabled
Y
no
= when in pause it stops
= disabled
Y
no
= when in pause it closes
= disabled
Y
no
= stops
= reverses
Y
no
= active
= disabled
Y
no
= active
= disabled
Y
no
= closes when released
= closes immediately
Y
no
= CLOSE stops
= CLOSE reverses
Y
= closes at the end of
no
opening
= immediate closing
Y
= moves in the opposite
no
direction
= always closes
Y
no
= closes when disengaged
= immediate reverse
Y
=
closing when FSW
no
is disengaged
= disabled
Y
= closes at the end of
no
opening
= disabled
Y
no
= closes when disengaged
= immediate reverse
Y
no
= closes if LOOP2 is clear
= disabled
Y
= closes at the end of
no
opening
= disabled
Y
no
= active
= disabled
Y
no
= closes if LOOP1 clear
= disabled
Y
no
= active
= disabled
Y
no
= active
= disabled