Changes  to  the  configuration  parameters  become 
effective immediately, while final storage occurs
only  upon  exiting  configuration  and  returning  to  the 
automated system status display. If the equipment is
powered down before returning to the automated system
status display, all changes made will be lost.
5.1 Basic configuration
To perform BASIC programming:
1.
Press and hold button F; the name of the first function is
displayed.
2.
Release the button; the function value is displayed and can be
modified using the + and - buttons.
Press and hold F again; the name of the following function is
3.
displayed, and so on.
The last function St lets you choose whether to save the configuration
Y
made (
) or exit without saving (
showing the automated system status
You can go to St at any time. To exit programming,
simultaneously press F and -.
BASIC CONFIGURATION
Display
Function
dF
Loading predefined parameter sets
00
Neutral condition
0 1
Minimum mass
06
Maximum mass
Before automated system start-up, you must
set the correct value, directly correlated to the
length of the beam and the number and type
of accessories installed. To determine said
value, refer to Tables 4 and 5 on page 24
WARNING: Setting a mass default
lower than the one actually
installed could cause irreversible
damage to the bar and barrier
structure.
If you do not wish to make any programming
changes, leave the value
selecting a value involves loading the chosen
predefined parameters set (see paragraph
5.2).
At
Currently loaded default
This menu indicates the currently loaded
default setting.
Given that parameter
predefined value (in order to provide a neutral
access condition to the parameters), using the
value in this menu makes it possible to identify
the currently configured default setting.
Read-only parameter
no
). Later, the display will resume
Default
00
00
, otherwise
06
dF
00
has
as the
Display
Function
bu
BUS accessories menu
For functions associated with this parameter
see paragraph 5.3
LO
Operating logics
A
Automatic
A 1
Automatic 1
E
Semi-automatic
P
Parking
PA
Automatic parking
Cn
Condo
CA
Automatic condo
C
Dead-man
CU
Custom
PA
Pause time
Is effective only if an automatic logic is
chosen; the value can be set from
59
sec. in one second steps. Next, the
display changes to minutes and tenths of a
second (separated by a decimal point) and
time is adjusted in 10-second steps up to the
maximum value of
e.g. if the display shows
will be 2 minutes and 50 seconds.
So
Opening speed
Adjusts the barrier opening speed.
00
Minimum speed
1 0
Maximum speed
WARNING: Setting an excessive speed
could cause irreversible damage to the
beam and barrier structure.
Sc
Closing speed
Adjusts the barrier closing speed.
00
Minimum speed
1 0
Maximum speed
WARNING: Setting an excessive speed
could cause irreversible damage to the
bar and barrier structure.
L 1
Loop 1
Activating this parameter, any loop that is
connected to the Loop 1 input will serve as
an OPEN function.
Y
Loop 1 enabled
no
Loop 1 disabled
Note: Should this function be disabled, the
detection status of the loop will in any case
remain available on one of the two outputs,
if configured (see parameters
Advanced Configuration)
9
Default
no
20
O
to
4.1
minutes.
2.5
, the pause time
02
no
o1
o4
...
in
E
10