10 Troubleshooting
L
8635
There is no comma within
the specified range of the
cell.
L
8640
Abnormal image capture
specification
L
8650
Put online.
L
8660
Not permitted to control
vision sensor
L
8670
Restart not possible after stop
10-139 Error list
There is no comma on the cell
which specifies it for Start Cell
and End Cell though the range
from 4 to 7 is specified for a
value of Type.
The
image
specification is other than
"camera",
"external",
"manual".
The vision sensor is offline.
The NVUSER and NVPSWD
parameters set for logging on
to the vision sensor do not
have the right to full access to
the vision sensor.
After the program was stopped, it
was started without being reset.
Check the value set to Type or
Start Cell and End Cell.
capture
Specify an
specification
and
"external", or "manual".
Put the vision sensor online to
enable
control
outside.
Check the vision sensor side
user
list
specify the name of a user
with full access in NVUSER
and
their
NVPSWD.
Reset the robot program, then
start it.
image
capture
of
"camera",
from
the
registration
and
password
in