4.2 Rotor interface design
To prevent magnet interference from affecting motor performance, there should be some space between
customer's shaft and rotor magnet. The recommended dimension of outside diameter(∅ ) inside
diameter(∅) and flatness specification of rotor mounting surface (Flatness A) is given in
Table 4.7, Table 4.8 。
Shaft
Type
TMRW1□/TM-2-1□
TMRW2□/TM-2-2□
TMRW4□/TM-2-4□
TMRW7□/TM-2-7□
TMRWA□/TM-2-A□
TMRWD□/TM-2-D□
TMRWG□/TM-2-G□
4-10
Figure 4.6 Rotor mounting interface (TMRW/TM-2)
Table 4.7 mounting interface suggestion (TMRW/TM-2)
∅
()
84.5
118
168
233
298
383
458
∅ .
∅ .
Rotor
Flatness A
∅
()
()
76.5
0.05
110/108.4
0.05
158.5
0.1
222.5/218.8
0.1
284.5
0.1
370
0.15
447
0.15
Motor Interface Design
Min. 1
Flatness B
()
0.05
0.05
0.1
0.1
0.1
0.15
0.15