3. SETUP

AC Power

This fixture has an auto-switching switch-mode power supply that can accommodate a wide range of
input voltages. The only thing necessary to do before powering on the unit is to make sure the line
voltage you are applying is within the range of accepted voltages. This fixture will accommodate
between 100V and 240V AC 50-60 Hz. All fixtures must be powered directly off a switched circuit and
cannot be run off a rheostat (variable resistor) or dimmer circuit, even if the rheostat or dimmer
channel is used solely for a 0% to 100% switch.
This fixture is designed for power linking from one COLORado™ Batten 80i to another COLORado™
Batten 80i fixture. Each fixture ships with Neutrik power input cables (standard Edison male-to-female
6ft A-type Neutrik 3-conductor connector).
Warning!
All fixtures must be connected to circuits with a suitable Earth Ground.
Depending on the application, the lighting fixture may require a different connector. Please refer to
the below factory-installed Neutrik twist-lock terminator wire color code if installing a wire connector.
Wire
Brown
Blue
Green/Yellow
COLORado™ Batten 80i User Manual
Connection
AC Live
AC Neutral
AC Ground
Connection
Pin
AC Live
1
AC Neutral
2
Ground(Earth)
3