DMX-512 addressing with ID address

1)
Follow instructions 1 ~ 4 for DMX512 addressing.
2)
Activate ID addressing in each fixture by setting panel function {ID ON/OFF} to ON.
{MENU}
3)
For every DMX512 starting address the user can set 66 separate ID addresses.
4)
Set ID addresses in each fixture by setting panel function {ID address} to incremental values.
(I.e. 1,2,3,4,5,6,etc...)
{MENU}
5)
ID addresses are accessible using Channel 10 [Stage 1+2].
6)
DMX 512 Controller

Setting the DMX address

Each fixture requires a "start address" from 1 to 512. A fixture requiring one or more channels for
control begins to read the data on the channel indicated by the start address. For example, a fixture
that occupies or uses 7 channels of DMX and was addressed to start on DMX channel 100, would
read data from channels: 100, 101, 102, 103, 104, 105 and 106. Choose start addresses so that the
channels used do not overlap and note the start address selected for future reference. The
COLORado™ 6 uses up to12 channels of DMX. If this is your first time using DMX, we recommend
reading the DMX Primer in the Appendix Section.

Control Panel Functions

All fixture functions and settings are accessible via the built in control panel interface.
MENU
UP
ENTER
DOWN
B
UTTON
MENU
DOWN
UP
ENTER
COLORado™ Batten 80i User Manual
{Settings)
{ID ON/OFF}
{Settings}
{ID address}
DMX Address: 001
DMX Address: 001
ID Address: 01
ID Address: 02
The figure above shows a simple DMX layout which has used three units at each
DMX address. The three units have different ID addresses which allows the user to
collectively control the whole group of units at that DMX address by setting Channel
10 to 0, or to control each unit independently by first selecting the DMX address and
then by using Channel 10 to locate the target ID address. (Note that when using ID
addresses it is also possible to activate ADAS which allows for even more option with
DMX addressing and control.
F
UNCTION
Exits from the current menu or function
Navigates downwards through the menu list and decreases the numeric value when
in a function
Navigates upwards through the menu list and increases the numeric value when in
a function
Enables the currently displayed menu or sets the currently selected value in to the
selected function
[ON]
[01 ~ 66]
DMX Address: 001
DMX Address: 013
ID Address: 03
ID Address: 01
15
DMX Address: 013
DMX Address: 013
ID Address: 02
ID Address: 03