1. Instruction format
TMR
TMR_A
Reset the timer and output:
S1: timer (T0, HT10)
S2: set time (such as K100)
S3: time unit (K1—1ms, K10—10ms, K100—100ms)
Power-off not retentive, not accumulation
(1) Time unit is 1ms, set time is K100, the real time is 1ms *100=0.1s
Set value is constant K
(2) Time unit is 10ms, set time is K10, the real time is 10ms*10=0.1s
Set value is constant K
(3) Time unit is 100ms, set time is K1, the real time is 100ms*1=0.1s
X0
Set value is constant K
Power-off retentive, accumulation
(1) Time unit is 1ms, set time is K100, the real time is 1ms *100=0.1s
X0
Set value is constant K
(2) Time unit is 10ms, set time is K10, the real time is 10ms*10=0.1s
S1
S2
S3
T0
K200
K10
S1
S2
S3
K10
T0
K2000
TMR
T0
K1
K100
TMR_A HT0 K100
K1
(Not accumulation)
(Accumulation)
set value is register D
set value is register D
set value is register D
set value is register D