C a t a l 1. XMP2-32 introduction ........................4 1-1 Performance and characteristic...................4 1-2 Specs ...........................4 1-2-1 General specs......................4 1-2-2 HMI specs........................5 1-2-3 PLC specs ........................5 1-2-4 Product type......................6 1-2-5 Name rule ........................6 1-3 Part name ..........................7 1-3-1 LED display......................8 1-3-2 Download port ......................8 1-3-3 Com port........................9 1-3-4 Port A and B ......................9...
1. XMP2-32 introduction 1-1 Performance and characteristic XMP2-32R-E ( relay output type ) and XMP2-32T-E ( transistor output type ) are integrated with HMI ( MP series ) and PLC ( XC2 series ) perfectly. They can totally instead of HMI and PLC in control system with the premiss of meeting the control requests.
Anti-jamming Voltage noise: 1000Vp-p Air condition No causticity gas Protect construction According to IP20 1-2-2 HMI specs Type TFT 256-colour LCD Screen dimension 7 inch Use life Over 50000 hours, 25! , 24 hours operating Display area 480*234 Characteristic Contrast Unable to change Character setting Chinese, English, Japanese, Korean, etc.
High speed processing High speed count0 pulse output0 external interrupt function Setting of time scan space 0~99mS Password protection 6 bits ASCII Self diagnose function Power on self-diagnose0 Monitor timer0 grammar check 1-2-4 Product type XMP-32 series Relay output Transistor output XMP2-32R-E XMP2-32T-E XMP2-32R-C...
1-3-1 LED display PWR: Power supply RUN: program running STOP: program stop 1-3-2 Download port The port is RS-232 standard and double function designed, is able to download PLC program and HMI program. Pin2 Pin3 Pin5 Pin7 Used as RS-485 com port: for HMI connecting with slave device Pin1 Pin9 PRT (when HMI connecting with slave device, short pin...
1-3-3 Com port The port is RS-232 standard, is used to connect PC and HMI. Pin2 Pin3 Pin5 1-3-4 Port A and B The port is RS-485 standard, is used to connect meter, inverter, extension model, etc. Attention: A, B port and RS-232 com port are the same port, can not be used at the same time. 1-4 Outline dimension Outline dimension ( mm ):...
Installate dimension ( mm ): 2. In-out specs and exterior layout 2-1 Input specs and layout Input specs: Input signal voltage DC24V± 10% Input signal current 7mA/DC24V Input ON current Above 4.5mA Input OFF current Below 1.5mA Input response time About 10ms Input signal format Point...
2 4 V - D C p o w e r 2 4 V + s u p p l y + 5 V C O M X 0 0 L E D I = 7 m A X 1 1 S e n s o r Input point arrangement: 2-2 Output specs and layout...
Page 12
Open creepage current < 0.1 mA Minimum load DC5V 2mA Response OFF!’ ON 0.2ms time ON!’ OFF 0.2ms Output connection figure: u Relay output: r c u i t c c i P L C b a s i b u r n i n g T o a v o i d n t s y 4 p o i...
3. PLC function and using 3-1 PLC instruction XMP2-32 series product used XC2 series PLC, the PLC instructions are the same as XC2-32. It contains SFC instructions, applied instructions and special function instructions. Please refer to XC Series PLC Manual: paragraph 4, 5,6.
3. Interrupt function Channel Input Pointer tag Disable interruption instruction Rising interruption Falling interruption CHL1 I0000 I0001 M8050 CHL2 I0100 I0101 M8051 CHL3 I0200 I0201 M8052 4. Frequency measurement The point is X1, X6, X7. 5. Pulse width modulation (PWM) The point is Y0, Y1.
Page 15
C300~C599ÿ 32 bits forth/back counter 0 C600~C6190 ÿ one phase high speed counter 0 C620~C6290 ÿ Pulse + direction high speed counter 0 C630~C6390 ÿ AB phase high speed counter D0~D999 2000 Data 0 D4000~D49990 register For special using D8000~D8511 D8630~D8729 FD0~FD127 Flash ROM...
3-3 Build a project XMP2-32 series products are integrated with XC series PLC and HMI. When editing PLC program, please use XCP Pro software which is the same as XC series PLC. 1. select the product type Open XCPPro, click “file---change PLC model”: Select “XMP2-32”:...
Page 17
3. download program After editing and saving the program, users need to download them to XMP. Before downloading, ensure the XMP has connected with computer successfully. (Please refer to chapter 1-3-2 for cable connection ). Click to open software serial port configuration Choose the correct serial port, baud rate and parity or click “check”...
3-4-1 Com port XMP2-32 series product have program port ( DB9 pins port ), RS-232 com port ( DB9 pins port ) and RS-485 com port ( A and B point ). Program port can only be used to download PLC program and HMI pictures.
Page 19
Station 1, baud rate 19200bps, 8 data bits, 1 stop bit, even check Station No. Modbus station No. : 1~254, 255(FF) is for free format communication Baud rate 300bps~115.2Kbps Data bit 8 or 7 bits Stop bit 2 or 1 bits Check Even, odd, no check Communication parameters setting are as below table:...
FD8226: 0ÿ 8 bits communication Reserved 1ÿ 16 bits communication 0: without start symbol 1: with start symbol 0ÿ without end symbol 1ÿ with end symbol 3-4-3 Communication mode Modbus communication XMP series product support master and slave mode of Modbus communication protocol. Master format: When PLC is set to be master station, PLC sends request to other slave station devices via Modbus instructions, other devices respond to the master station.
Data Block (max bytes 128 ) End Symbol (1 byte) 4. HMI function and using 4-1 HMI function The HMI part of XMP2-32 series product is integrated with MP-760T touch screen. The faceplate key-presses are as below: Function Running the program, LED indication light...
Page 22
Turn the screen to the next page Inquiry, jump to the user appointed screen To write the modified value in the register and continue modifying next register. After the last register in the screen has been modified, it will quit the setting.
4-2 Build a project Please use Touchwin software. Open the software, click “File---New” or click to build a new project. Choose “MP760-T(XMP-32)” in the panel window: Click “next”, choose “Xinje XC series” for PLC port device:...
Page 24
Click “next”, choose “Unuse download port” for download port device: Click “next” to complete the building. The editing interface is as below: The software using details please refer to TP Touch Screen Operating Manual.
5. The extension ability 5-1 Summarization XMP2-32 series product can not extend BD board. For extending other devices, use RS-232 or RS-485 ( point A and B ) com port. RS-232 com port can connect with computer, HMI to monitor the program.
Meter module 5-2. Extend MA model XMP2-32 series product can extend MA model via RS-485 com port (A and B point) in order to control and measure analog quantity. The type and specs of MA model are as below: MA model type...
Page 27
Type Description MA-8X8YR 8 channels digital input,8 channels digital relay output MA-16X 16 channels digital input MA-16YR 16 channels digital relay output MA-16YT 16 channels digital transistor output MA-4DA Item Voltage output Current output DC0ÿ ^ 5V0 0ÿ ^ 10V DC0ÿ...
Page 28
Analog input range 0~5V,0~10V 0~20mA,4~20mA Maximum input range DC± 18V 0~40mA Digital output range 12 bits binary value (0~4095) Resolution 1/4095(12Bit) PID output range 0~K4095 Integrated precision 0.8% Converting speed 20ms per channel Power for analog DC24V±10%ÿ 100mA Installation Fix up the module with M3 screw or put on DIN46277 rail (width 35mm) Profile dimension 63mm×102mm×73.3mm MA-4AD2DA...
Page 29
Integrated precision Conversion speed 20ms/1 channel Power supply for analog DC24V± 10%, 50mA Installation Use M3 screw or fix on DIN46277 ( width 35mm ) rail Profile dimension 63mm×102mm×73.3mm MA-6PT-P Item Description Analog input signal Pt100 Pt hot resistance Measure temperature range -100!ÿ^ 350! Digital output range Full-scale 4095, 12 bits with sign, binary...