LD
SM0
TRD
D0
K30
LD>= D2
AND>=
D1
AND>=
D0
K7
LD>= D1
AND>=
D0
ORB
K13
OR>= D0
D4000 K1234
DAND<>
SET
SM34
DLD= D4000 K1234
RST
SM34
//SM0 is always ON coil
//read the RTC (real time clock) value and store in D0~D6
//RTC date ≥30
K6
//RTC month ≥6
K12
//RTC year ≥12
//or RTC month ≥ 7
K12
//RTC year ≥ 12
//or
//RTC year ≥ 13
//and password ≠1234
//set ON M34, all the outputs are disabled
//password=1234, correct password
//reset M34, all the outputs are enabled