PLC model
XDME
XDH
XL1
XL3
XL5
XL5E
XL5E
XLME
Each letter's Meaning:
U
Pulse input
X can use as normal input terminals when there are no high speed pulses input. In the
following table, Frequency doubling 2 means 2 frequency doubling; 4 means 4 frequency
doubling; 2/4 means 2 and 4 frequency doubling.
Note: Z phase signal counting function is in developping.
HSC0 HSC2 HSC4 HSC6 HSC8 HSC10 HSC12 HSC0
Max
10K
10K
frequency
Frequency
doubling
Counter
interruption
X000
U
X001
X002
X003
U
X004
X005
X006
X007
X010
HSC0
HSC2 HSC4 HSC6 HSC8 HSC10 HSC12 HSC0
Max
80K
10K
frequency
Frequency
doubling
Counter
interruption
X000
U
X001
X002
X003
30T4/60T4
60T10
60T4
16
16/32
16/32
32T4
16/32
32T4
64T6
32T4
A
A phase input
Increasing mode
10K
U
XD2-24/32, XD3-16/24/32, XL3-16/32
Increasing mode
10K
U
HSC channel
Incremental
AB phase mode
mode
4
10
4
0
3
3
4
3
4
6
4
B
B phase input
XD2-16
5K
2/4
A
B
Z
50K
2/4
A
B
Z
181
4
10
4
0
3
3
4
3
4
6
4
Z
Z phase pulse catching
AB phase mode
HSC2
HSC4
HSC6
5K
5K
2/4
2/4
A
B
Z
A
B
Z
AB phase mode
HSC2
HSC4
HSC6 HSC8
5K
5K
2/4
2/4
A
HSC8