Xinje XD Series User Manual page 265

Hide thumbs Also See for XD Series:
Table of Contents

Advertisement

program is written according to the data format obtained, which is often twice the result with
half the effort.
In fact, Modbus-RTU protocol can be regarded as a special kind of free protocol. The
relationship between them is similar to ellipse and circle. We can try to use free format to
realize the function of Modbus instruction.
Example 2: The values of the five registers of a XD3 PLC are sent to the D1-D5 of another
XDM PLC.
If the user understands the Modbus communication, he can use the Modbus-RTU
communication mode to do so, as long as he writes a "write multiple register instructions
(MRGW)" in the host. Here we do it in free communication mode.
Operation steps:
1. Connect the hardware first. Here we use the serial port 2 of the PLC to communicate, that
is, connect A of the two PLC, and connect B of the two PLC.
2. Set the same serial port parameters of the two PLC. The parameters are set as follows.
After setting the parameters, the power can be restarted.
3. XD3 program:
SM2
SM13
MOV
MOV
MOV
MOV
MOV
SEND HD1
264
H1122
HD1
4366
H3344
HD2
13124
H5566 HD3
21862
H7788
HD4
30600
H99AA
HD5
-26198
K10
K2
4386

Advertisement