SM0
M0
M1
FEND
I2000
SM0
IRET
I2001
SM0
IRET
Instruction:
LD
SM0
DMOV K10000 HD0
DMOV K-10000 HD2
DMOV K200000 D10
LD
M0
CNT_AB HSC0 D10 HD0
LDP
M1
RST
HSC0
FEND
I2000
LD
SM0
INC
D0
IRET
I2001
LD
SM0
INC
D1
IRET
DMOV
K10000
HD0
DMOV
K-10000
HD2
DMOV
K200000
D10
CNT_AB
HSC0
RST
HSC0
INC
D0
INC
D1
//SM0 is normally ON coil
//segment one preset value HD0 is 10000
//segment 2 preset value HD2 is -10000
//set HSC compare value
//HSC activate condition M0
//HSC interruption instruction
//HSC reset condition M1
//reset HSC and 100 segments interruption
//the main program end
//segment one interruption flag
//SM0 is normally ON coil
//D0= D0+1
//interruption return flag
//segment 2 interruption flag
//SM0 is normally ON coil
//D1= D1+1
//interruption return flag
207
D10
HD0