Xinje XD Series User Manual page 160

Hide thumbs Also See for XD Series:
Table of Contents

Advertisement

D
The compare result soft element address
3. Suitable soft components
Operand
Word
S1
S2
S3
Operand
Bit
D
*Notes: D includes D, HD; TD includes TD, HTD; CD includes CD, HCD, HSCD, HSD;
DM includes DM, DHM; DS includes DS, DHS.
M includes M, HM, SM; S includes S and HS; C includes C and HC.
Description
Compare the source data with the range
X0
EZCP
M3
M4
M5
When X0 is OFF, even EZCP doesn't run, M3~M5 will keep
the status before X0 is OFF.
Compare the source data S3 to the upper and lower limit value of the range S1~S2.
The result will store in three coils starting from D.
Constant K and H will transform to binary floating value when they are source data.
X0
EZCP
(K10) : [D6,D5] : (K2800) → M0, M1, M2
Binary converts Binary Floating Binary converts
to Floating
System
*
*
*
D
FD
TD
CD
DX
System
*
*
*
*
X
Y
M
S
T
C
S1·
S2·
S3·
D10
D20
D0
(D1, D0)
Binary Floating
(D11, D10)
Binary Floating
(D1, D0)
Binary Floating
K10
K2800
D5
bit
Constant
*
*
DY
DM
DS
K /H
Dn.m
M3
< (D11, D10)
Binary Floating
≤ (D1, D0 )
Binary Floating Binary Floating
> (D21, D20)
Binary Floating
M0
to Floating
159
Module
ID
QD
ON
≤ (D21, D20) ON
ON