Perkins 904F-E28T Operation And Maintenance Manual page 91

Industrial engine
Table of Contents

Advertisement

M0125147
Illustration 51
Typical example
8. Remove the filter element (4). Clean the filter bowl.
Install the New Filter Element
Illustration 52
Typical example
Fuel System Primary Filter (Water Separator) Element - Replace
1. After repositioning the self-venting drain up, locate
the thread in the new filter element (6) onto the
thread (7). Spin on the filter element and tighten
the drain valve (2) securely.
2. Lubricate the lip (Position (X) ) with clean engine
oil. Do NOT fill the bowl with fuel before the
assembly is installed.
Note: Do not use a tool to install the filter assembly.
3. Align the filter bowl (5) to the assembly. Rotate the
filter bowl (5) clockwise by hand. Rotate the filter
bowl (5) until there is no visible gap between the
element and the filter bowl and the assembly.
4. Remove the container and dispose of the fuel in a
safe place.
5. Install the wiring harness to connection (3).
6. The secondary filter element (if equipped) must be
replaced at the same time as the primary filter
g06304508
element. Refer to the Operation and Maintenance
Manual, "Fuel System Secondary Filter - Replace".
Fuel System Primary Filter (Water
Separator) Element for Manual Fuel
Priming Pump
Remove the Element
1. Turn the fuel supply valve (if equipped) to the OFF
position before performing this maintenance.
2. Place a suitable container under the water
separator to catch any fuel that might spill. Clean
up any spilled fuel. Clean the outside body of the
filter assembly.
g06304524
91
Maintenance Section

Advertisement

Table of Contents
loading

Table of Contents