Battery Or Battery Cable - Disconnect; Belt - Inspect - Perkins 904F-E28T Operation And Maintenance Manual

Industrial engine
Table of Contents

Advertisement

M0125147
All lead-acid batteries contain sulfuric acid which
can burn the skin and clothing. Always wear a
face shield and protective clothing when working
on or near batteries.
1. Remove the filler caps. Maintain the electrolyte
level to the "FULL" mark on the battery.
If the addition of water is necessary, use distilled
water. If distilled water is not available use clean
water that is low in minerals. Do not use artificially
softened water.
2. Check the condition of the electrolyte with a
suitable battery tester.
3. Install the caps.
4. Keep the batteries clean.
Clean the battery case with one of the following
cleaning solutions:
• Use a solution of 0.1 kg (0.2 lb) baking soda
and 1 L (1 qt) of clean water.
• Use a solution of ammonium hydroxide.
Thoroughly rinse the battery case with clean
water.
Battery or Battery Cable -
Disconnect
The battery cables or the batteries should not be
removed with the battery cover in place. The bat-
tery cover should be removed before any servic-
ing is attempted.
Removing the battery cables or the batteries with
the cover in place may cause a battery explosion
resulting in personal injury.
1. Turn the start switch to the OFF position. Turn the
ignition switch (if equipped) to the OFF position
and remove the key and all electrical loads.
Note: After the engine has stopped, allow 2 minutes
for the storing of information from the engine to the
ECM before disconnecting the power.
2. Disconnect the negative battery terminal. Ensure
that the cable cannot contact the terminal. When
four 12 V batteries are involved, 2 negative
connections must be disconnected.
3. Remove the positive connection.
4. Clean all disconnected connection and battery
terminals.
5. Use a fine grade of sandpaper to clean the
terminals and the cable clamps. Clean the items
until the surfaces are bright or shiny. DO NOT
remove material excessively. Excessive removal
of material can cause the clamps to fit incorrectly.
Coat the clamps and the terminals with a suitable
silicone lubricant or petroleum jelly.
6. Tape the cable connections to help prevent
accidental starting.
7. Proceed with necessary system repairs.
8. To connect the battery, connect the positive
connection before the negative connector.

Belt - Inspect

i08046521
Illustration 33
Typical example
To maximize the engine performance, inspect the
belt (1) for wear and for cracking. Replace the belt if
the belt is worn or damaged.
Maintenance Section

Battery or Battery Cable - Disconnect

75
i07380538
g06301080

Advertisement

Table of Contents
loading

Table of Contents