Appliance Data - Baxi 755 Installer's Manual

Remote control inset live fuel effect gas fire
Table of Contents

Advertisement

Gas
Inlet Pressure
Input Max. (Gross)
Input - Min. (Gross)
Inlet Test Pressure (Cold)
Gas Connection
Burner Injector
Pilot & Atmosphere Sensing
Device
Ignition
Aeration
* When converted using conversion kit number 05754M1.
The appliance data label is located on a plate at the base of the fire. This can be seen by
lowering the bottom front cover of the fascia.
The efficiency of this appliance has been measured as specified in BS 7977 - 1 and the
result is as below :
Model
Fascination.
Fascination when converted to LPG.
The gross calorific value of the fuel has been used for this efficiency calculation. The
test data from which it has been calculated has been certified by Advantica Certification
services (0087). The efficiency value may be used in the UK Government's Standard
Assessment Procedure (SAP) for energy rating of dwellings.
The convertion of net efficiency to gross was achieved by multiplying the net efficiency
by the following conversion factor from Table E3 of SAP 2005, rounding down to the
nearest whole number.
©
Baxi Heating U.K. Limited 2006.
INSTALLER GUIDE

3. APPLIANCE DATA

Natural (G20)
20mbar
5.5kW (18,766 Btu/h)
3.1kW (10,577 Btu/h)
20.0 ± 1.0mbar (8.0 ± 0.4in
w.g.)
8mm pipe
Stereomatic Cat. 82 Size 065
Copreci Ref. O.D.S
21500/194
Electronic
Non-adjustable
Page 6
Propane (G31)*
37mbar
5.0kW (17,060 Btu/h)
4.6kW (15,695 Btu/h)
37.0 ± 1.0mbar (14.85 ±
0.4in w.g.)
8mm pipe
StereomaticSize 110
Copreci Ref. O.D.S
21500/194 Fitted with RBM
180 - 02 injector
Electronic
Non-adjustable
Efficiency % (Gross)
48
50

Advertisement

Table of Contents
loading