A nut and olive are provided for an 8mm pipe inlet connection to the 'T' connector at
the bottom front of the appliance. The 'T' connector can be rotated to allow a
connection from any rear-concealed connection. The 'T' connector includes a valve for
isolating the gas supply and a pressure test point.
The supply pipe must be rigid material. Flexible pipe must not be used.
Concealed supply pipe connection.
If a concealed connection from inside the fireplace is required then, before the
appliance is fitted into the fireplace it will be necessary to extend the supply line so
that it will project through the hole in the back of the hotbox and run to the 'T'
connector at the front. The pipe run from the supply line up to the rear opening in the
hotbox must be kept away from the area which will be taken by the hotbox when it is
installed. Note that the centre of the appliance inlet 'T' connector is 25mm above the
fireplace floor. The inlet 'T' connector should be fitted to the supply pipe at this stage.

9. PREPARING APPLIANCE FOR INSTALLATION

1. Detach the spillage plate from the hotbox by removing
the four screws (See figure 9).
2. Remove the protective film (Where fitted) from the
spillage plate. Place the spillage plate in a safe place
away from the work area.
3. Remove the six screws from the side of the inner
reflector (See figure 10).
4. Carefully lift the inner reflector and pull forward to
remove. Be careful not to scratch the top surface of
the burner cover (See figure 10). The reflector may
'spring' a little. For this reason it is important to hold
the edges firmly when removing.
5. Remove the protective film from the inner reflector.
Place the inner reflector in a safe place away from the
work area.
6. Remove the two screws to the side of the burner cover (See figure 11)
7. Detach the burner cover by lifting clear of the burner module (See figure 11)
8. Remove the protective film (Where fitted) from the burner cover. Place the burner
cover in a safe place away from the work area.
9. Detach the burner unit from the hotbox by lifting clear.
10. Fit the two "U" section seals to the bottom edges of the hotbox side flanges (See
figure 12).
©
Baxi Heating U.K. Limited 2006.
INSTALLER GUIDE

8. GAS SUPPLY CONNECTION

Page 18
Figure 9. Spillage plate
removal