Burner & Supply Pipe Installation - Baxi 755 Installer's Manual

Remote control inset live fuel effect gas fire
Table of Contents

Advertisement

11. BURNER & SUPPLY PIPE INSTALLATION
11.1 Fitting the burner.
1. Place the burner module into the hotbox.
2. Refit the burner cover by lowering it onto the burner
module. The front edge of the burner cover should locate in
front of the burner module. The sides of the burner cover
should locate behind the front of the burner module. Secure
with two screws removed previously (See figure 23)
3. Refit the Inner Reflector into the hotbox. Be careful not
to scratch the top surface of the burner cover. Secure using
six screws removed previously.
4. Refit the spillage plate. Secure using the four screws
removed previously.
11.2 Supply pipe installation.
A nut and olive is provided for an 8mm-pipe inlet
connection directly to the gas control. The isolating 'T'
connector can be rotated to allow a connection from any
direction. The 'T' connector includes a valve for isolating
the gas supply.
The supply pipe must be rigid material. Flexible pipe must not be used. Connect the
supply line to the appliance.
Turn on the gas supply and pressure check the installation pipework for gas soundness.
In the United Kingdom (GB) check in accordance with the current edition of BS 6891.
In the Republic of Ireland check in accordance with the current edition of IS 813
"Domestic Gas Installations"
11.3 Preliminary burner checks.
Some burner operations can be checked at this stage. Checking now will mean that less
disassembly will be required if any problems are found. A full check should still be
made, however, after final installation.
11.3.1 Lighting the fire.
If closed
open the isolating 'T' connector valve.
,
xPress the on-off button
start to flash in the top left hand corner of the display screen).
xPress the 'SET' button. The L.E.D. light on the bottom left hand side of the fire will
illuminate and a small twin flame symbol will flash on the handset. The flame symbol
will stop flashing when the ignition sequence has been completed. When the 'SET'
button is pressed there will be a slight delay and several sparks should be seen between
©
Baxi Heating U.K. Limited 2006.
INSTALLER GUIDE
on the remote control handset (The word 'ON' will now
Page 24
Figure 23. Burner cover
location

Advertisement