11. Pull each cable taut. Push the cable retainers hard up against the back panel. The end
of the cable adjuster will pass into the hole. Tighten the screws in the retainers so that
they clamp the cables in position. Apply tension to the cables by turning the hexagonal
adjusters by hand (See figure 21).
12. Inspect the installation of the hotbox against the fireplace surround. If the hotbox is
aligned squarely and the sealing is satisfactory,
fully tighten the cable retainers.
13. If the hotbox is not correctly aligned,
release the tension on the cables by slackening
the screws and turning the hexagonal adjusters
fully anticlockwise. The hotbox should then
automatically realign itself. Pull each cable
taut again and push the cable retainers back
against the back panel. Again, tighten the
screws in the retainers and apply tension to the
cables by turning the hexagonal adjusters
clockwise as far as possible.
14. Feed the free length of the cables into the
Figure 21. Lower cable retention
gap between the inner and outer back panels
so that they are available to allow easy
removal and refitting of the appliance during
subsequent service calls. Do not cut off the free
lengths of cable. On precast flue installations feed
the cables into the small holes at the base of the side
panels.
10.3 Sealing floor front - all installations.
Using the floor sealing tape supplied, seal the bottom
of the hotbox to the fireplace and hearth floor (See
Figure 22. Floor sealing
figure 22).
Make sure that the whole length of the front edge of the hotbox is fully sealed.